1-3. TROUBLESHOOTING (Continued)
Problem
With switch in
POWER position,
the fryer is completely
inoperative
(no power)
Pressure will not
exhaust at end of
cook cycle
Operating
pressure too high
DO NOT OPERATE UNIT. IF HIGH PRESSURE CONDITIONS EXIST, SEVERE
INJURIES AND BURNS WILL RESULT. PLACE THE POWER/PUMP SWITCH IN THE
OFF POSITION IMMEDIATELY. RELEASE THE PRESSURE BY ALLOWING UNIT TO
COOL. THE PRESSURE WILL THEN DROP. DO NOT RESUME USE OF UNIT UNTIL
CAUSE OF HIGH PRESSURE HAS BEEN FOUND AND CORRECTED.
Sept. 2004
Cause
POWER SECTION
Open circuit
PRESSURE SECTION
Exhaust line from solenoid
valve to exhaust tank
clogged
Solenoid valve clogged
Deadweight clogged
Exhaust line to stack clogged
1-6
Model 691
Correction
Check to see that unit is
plugged in
Check the breaker or fuse
at supply box
Check voltage at wall
receptacle
Check POWER switch;
replace if defective
Check cord and plug
Turn unit off and allow
fryer to cool to release
pressure from frypot;
clean all pressure lines,
exhaust stacks, and exhaust
tank
Check and clean solenoid
valve
Turn unit off and allow
fryer to cool to release
pressure from frypot;
remove deadweight and clean
Clean exhaust line to stack