2-12. LID COUNTERWEIGHT
CABLES (Continued)
Sept. 2004
9. Remove the Allen head bolts securing the stabilizer bracket
and remove the bracket.
10. Remove the bolts and spacers securing the pulley bracket,
and pull bracket back, to allow access to cable bracket.
11. Pull cable and bracket from unit and remove cable from
bracket.
12. Remove cable from weight frame.
13. Thread new cable through pulley.
14. Thread nut on cable and place cable through weight frame.
15. Thread second nut onto end of cable, but do not tighten.
16. Thread nut on other end of cable and place through the
bracket, then thread a second nut on the end of the cable.
Tighten the nut to the bracket. Two inches (50.8 mm) of the
threaded end should show above the bracket. See photo below.
2 inches (50.8 mm)
Both cables should have same amount of threads extending
through the brackets.
17. Tighten cable onto weight frame.
18. Reassemble in reverse order.
Be sure to use pipe sealant on the pipe fittings.