Inspect the counterweight cables. If cables have cracks in the jacket, missing pieces in the jacket, any
fraying wires, or other obvious signs of wear, stop. Take the fryer out of service until the cables are
replaced. See figures 8 - 11 on page 5 for an example of good cables and an example of cables
that need to be replaced.
If cables are 10 years old or older, they must be replaced regardless of inspection results. For cables that
do not pass inspection, replace with Kit #140225, following all instructions included with the kit.
Model 690 SN: AP0802028 & earlier
Figure 5.
Models 680, 580, 590, and 690 SN:
AP0802029 & after
Figure 6.
Inspection 5
Rev A