1-3. TROUBLESHOOTING (Continued)
Problem
HEATING OF SHORTENING SECTION (Continued)
Heating of
shortening too
slow
Shortening
overheating
Sept. 2004
Cause
Supply line too small; low
gas volume
Improper ventilation
system
Improper air flow to burners
Programming wrong
Faulty PC Board
Faulty temperature probe
1-9
Model 691
Correction
Increase supply line size
Refer to installation
instructions
Refer to installation
instructions
Observe burners
Check gas pressure
Check blower for resriction of
airflow
Check temperature setting
in the program mode
Remove and replace control
panel
Remove and replace tempera-
ture probe