Henny Penny PFG-691 Technical Manual page 133

Pressure fryer
Hide thumbs Also See for PFG-691:
Table of Contents

Advertisement

2-20. BLOWER ASSEMBLY
The blower motor circulates air into the burner
area to create the correct heat for the fryer. If the
blower fails, a sensor will shut the power control
valve down.
1. Make sure unit is off, and close and lock
the lid.
Lid should be in locked down position. Failure
to do so could result in personal injury.
2. Remove the back shroud of the unit.
3. Using a Phillip's-head screwdriver,
remove the screw securing the flue to the
blower.
4. Using a 3/8" socket or wrench, remove
the 5 nuts securing blower motor and pull
motor from unit.
Blower Motor
5. Disconnect wires at junction box.
6. Remove the blower from unit.
7. Replace new blower in reverse order of
procedures.
Inspection 8