Power Cord
Replace any power cord with torn or damaged sheathing, any exposed wire, or any fraying.
Replace the plug if there are any signs of damage, loose wires showing, burnt connections.
Guidelines from the manual are listed below.
2-6. ELECTRICAL The electric fryer requires 208 or 240 volt, three phase, 50/60
REQUIREMENTS Hertz service. The power cord may be already attached to the
fryer, or provided at installation. Check the data plate mounted just
above the lid, on the left side of the back shroud, to determine the
correct power supply.
This fryer must be adequately and safely grounded
(earthed) or electrical shock could result. Refer to local
electrical codes for correct grounding (earthing) procedures
or in absence of local codes, with The National
Electrical Code, ANSI/NFPA No. 70-(the current edition).
In Canada, all electrical connections are to be
made in accordance with CSA C22.1, Canadian Electrical
Code Part 1, and/or local codes.
To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors. The
main power switch on this appliance does not disconnect
all line conductors.
A separate disconnect switch with proper capacity fuses or breakers
must be installed at a convenient location between the fryer and
the power source. It should be an insulated copper conductor
rated for 600 volts and 90
(15.24 m), use the next larger wire size.
2-7. INTERNATIONAL Units being used outside the United States may not be shipped
ELECTRICAL with the power cord attached to the unit because of the different
REQUIREMENTS wiring codes. The fryers are available from the factory wired for
208, 240, 380 and 415 volts, 3 phase, 50 Hertz service. A terminal
block is mounted inside the fryer for the cable wiring. A decal on
the inside of the right side panel will help in the wiring of the unit.
CE units require a minimum wire size of 4mm to be wired to
the terminal block. If a flexible power cord is used, it must be
1219 US 35 West P.O. Box 60 Eaton, OH 45320 (937)456-8400 Fax (937)456-8402 www.hennypenny.com
Fire Risk and Electrical Shock Possible. If any of these
conditions are found, take the fryer out of service until a new
power cord or plug can be installed. Always adhere to local
electrical code upon installation of the power cord.
C. For runs longer than 50 feet
o
Inspection 3
Rev. A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents