Table 2-11 Coil Check Procedure; Figure 2-17 Solenoid Valve Assembly - Henny Penny 600 Service Manual

4-head gas pressure fryers
Hide thumbs Also See for 600:
Table of Contents

Advertisement

Test Volts/Phase
24 volt
120 volt 60 Hz
208-240 volt 60 Hz
208-240 volt 50 Hz
2 2 . . 1 1 7 7 . . 3 3 R R e e p p l l a a c c e e m m e e n n t t
Remove Tru-Arc retaining clip on top of the coil housing.
1 1 ) )
Remove the nameplate and cover.
2 2 ) )
If only the coil is replaced, disconnect two coil wires at the wire nuts in the coil
3 3 ) )
housing, and remove the coil from the housing. Then replace nameplate, cover,
and Tru-Arc clip. If the complete solenoid or seal are being replaced, continue to
step 4.
NOTICE:
46
T T a a b b l l e e 2 2 - - 1 1 1 1 C C o o i i l l C C h h e e c c k k P P r r o o c c e e d d u u r r e e
Results
2.2 Ohms
50 Ohms
150 Ohms
245 Ohms

Figure 2-17 Solenoid Valve Assembly

The wires may be connected in any order.

Hide quick links:

Advertisement

Table of Contents