0: Off; Min To Max - IAI GO-2400M-PMCL User Manual

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

LUTMode
R/W
AlcSpeed
R/W
AwbSpeed
R/W
ExposureAutoMax
R/W
ExposureAutoMin
R/W
AlcReference
R/W
GainAutoMax
R/W
GainAutoMin
R/W
ALCChannelAreaAll
R/W
ALCChannelArea
R/W
LowRight
ALCChannelArea
R/W
LowMidRight
ALCChannelArea
R/W
LowMidLeft
ALCChannelArea
R/W
LowLeft
ALCChannelArea
R/W
MidLowRight
ALCChannelArea
R/W
MidLowMidRight
LUTC

0: Off

1: Gamma
2: LUT
ALCS

Min to Max

AWBS
Min to Max
ASCEA
Min to Max[us]
ASCEI
Min to Max
AGCF
Min to Max[%]
AGCGA
Min to Max
AGCGI
Min to Max
ALCA
0: Off / 1: On
ALCLR
0: Off / 1: On
ALCLMR
0: Off / 1: On
ALCLML
0: Off / 1: On
ALCLL
0: Off / 1: On
ALCMLR
0: Off / 1: On
ALCMLMR
0: Off / 1: On
0
2
0
1
8
4
1
8
4
101
8000000
18000
100
7999999
100
1
100
50
101
1600
1600
100
1599
100
0
1
0
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
̶ 85 ̶
GO-2400M-PMCL / GO-2400C-PMCL
LUTC=[Param.]<CR><LF>
Select the JAI LUT
LUTC?<CR><LF>
mode.
ALCS=[Param.]<CR><LF>
Set the control
ALCS?<CR><LF>
speed for AGC and
for AGC and ASC
ASC (8 is the
fastest).
AWBS=[Param.]<CR><LF>
Set the control
AWBS?<CR><LF>
speed for Balance
for AWB
White Auto (AWB)
(8 is the fastest).
ASCEA=[Param.]<CR><LF>
Set the maximum
ASCEA?<CR><LF>
value for the
Maximum value is varied
Exposure Auto
depending on frame rate.
(ASC) control
range.
ASCEI=[Param.]<CR><LF>
Set the minimum
ASCEI?<CR><LF>
value for the
Maximum value is varied
Exposure Auto
depending on frame rate.
(ASC) control
range.
AGCF=[Param.]<CR><LF>
Set the target
AGCF?<CR><LF>
level for ALC.
(unit: %)
AGCGA=[Param.]<CR><LF>
Set the maximum
AGCGA?<CR><LF>
value for the Gain
Auto (AGC)
control range.
AGCGI=[Param.]<CR><LF>
Set the minimum
AGCGI?<CR><LF>
value for the Gain
Auto (AGC)
control range.
ALCA=[Param.]<CR><LF>
On: Specify all
ALCA?<CR><LF>
photometry areas
for ALC,
regardless of the
enabled/disabled
statuses
configured
individually for
each photometry
area with [ALC
Area Selector].
Off: Specify areas
for ALC based on
the enabled/
disabled statuses
configured
individually for
each photometry
area with [ALC
Area Selector].
ALC**=[Param.]<CR><LF>
Enable/disable
ALC**?<CR><LF>
the Low Right
photometry area.
Enable/disable the
Low Mid Right
photometry area.
Enable/disable the
Low Mid Left
photometry area.
Enable/disable
the Low Left
photometry area.
Enable/disable the
Mid Low Left
photometry area.
Enable/disable
the Mid Low Mid
Right photometry
area.

Advertisement