Video Send Mode

Switch the video send mode to configure and operate Sequence Trigger and other JAI Custom Control
functions.
Video Send Mode

■ To switch the video send mode

Select the video send mode in [Video Send Mode Selector].
[Video Send Mode Selector] option
Normal Mode

Trigger Sequence Mode

Command Sequence Mode
■ Trigger Sequence mode
The Sequence Trigger function lets you define up to 128 preset combinations of exposure time,
gain, ROI, and other settings which can be stepped through each time a trigger is received. This is
particularly useful for quickly capturing multiple exposures of objects under inspection to adjust for
areas or components with significantly different levels of reflectance. The order of execution and the
repetition of particular presets are based on user-defined parameters stored in the sequence, as well
as the sequence mode selected in the [Video Send Mode Selector].
Two operation modes (Trigger Sequence and Command Sequence) are available for the Sequence
Trigger function.
Trigger Sequence mode
With this mode, the Sequence Trigger "pattern" is predetermined by the user. The user defines up to
128 different "indexes." Each index represents a combination of the following parameters:
• ROI (width, height, offset X, and offset Y)
• Exposure Time
• Gain Level (R/B Gain can also be configured on the color model)
• Black Level
• Binning Mode (monochrome only)
• LUT Enable (whether or not to enable the use of LUT for this index)
• Frame Count (the number of times to repeat this index before moving to the next)
• Next Index to execute in the predetermined pattern
In addition to these individual index parameters, two other parameters are applied to the entire
sequence:
[Sequence LUT Mode] defines whether Gamma or LUT is to be applied to the sequence. If Gamma
is selected, the Gamma setting defined in the camera's Analog Control section will be applied to all
exposures in the sequence. If LUT is selected, the LUT characteristics defined in Analog Control will
be applied to any index where [Sequence LUT enable] has been set to ON.
Normal camera operation.
Sequence Trigger mode.
Sequence Trigger mode that executes presets in a predefined order
based on [Sequence Roi Frame Count] and [Sequence Roi Next
Index]. Starts at Index #1.
Sequence Command mode.
Sequence Trigger mode that executes the preset listed in
[Command Sequence Index] each time a trigger is received. Can
jump to new preset by sending a new index value to [Command
Sequence Index].
̶ 45 ̶