3 Power/trigger LED
Indicates the power and trigger input status.
LED status and camera status
LED
Power / trigger LED
4 DC IN / trigger IN connector (4-pin round)
Connect the cable for a VA-044G Power Supply (optional) or for DC IN /trigger IN here.
2
1
3
4
Compatible connectors
Camera side: 09-3111-81-04 (Binder)
Cable side:
79-3108-52-04 (Binder) AWG 26
Pin No.
Input/output
1
Power In
2
In
3
Out
4
Out
Light
Camera initializing.
Lit amber
Operational and no triggers being input.
Lit green
Operational and triggers being input.
Blinking green
The blinking interval is not related to the actual input interval
of the external trigger.
or
79-3108-32-04 (Binder) AWG 24
Signal
DC (+12 V) In
DC 12 V to 24 V +/– 10%
TTL In
Line 4
TTL Out
Line 1
Power GND
COMMON GND
̶ 10 ̶
GO-2400M-PMCL / GO-2400C-PMCL
Status
Description