IAI SP-20000M-CXP2 User Manual

20 mp cmos digital progressive scan monochrome and color camera spark series
Table of Contents

Advertisement

Quick Links

Spark Series
User Manual
SP-20000M-CXP2
SP-20000C-CXP2
20 MP CMOS Digital Progressive Scan
Monochrome and Color Camera
Document Version:Ver.1.6
SP-20000-CXP2_Ver.1.6_May2015
1049E-1312

Advertisement

Table of Contents
loading

Summary of Contents for IAI SP-20000M-CXP2

  • Page 1 Spark Series User Manual SP-20000M-CXP2 SP-20000C-CXP2 20 MP CMOS Digital Progressive Scan Monochrome and Color Camera Document Version:Ver.1.6 SP-20000-CXP2_Ver.1.6_May2015 1049E-1312...
  • Page 2: Sp-20000M-Cxp2 / Sp-20000C-Cxp

    CE compliance As defined by the Directive 2004/108/EC of the European Parliament and of the Council, EMC (Electromagnetic compatibility), JAI Ltd., Japan declares that SP-20000M-CXP2 and SP-20000C-CXP2 comply with the following provisions applying to its standards. EN 61000-6-3 (Generic emission standard part 1)
  • Page 3 SP-20000M-CXP2 Supplement The following statement is related to the regulation on “ Measures for the Administration of the control of Pollution by Electronic Information Products “ , known as “ China RoHS “. The table shows contained Hazardous Substances in this camera.
  • Page 4 SP-20000C-CXP2 Supplement The following statement is related to the regulation on “ Measures for the Administration of the control of Pollution by Electronic Information Products “ , known as “ China RoHS “. The table shows contained Hazardous Substances in this camera. mark shows that the environment-friendly use period of contained Hazardous Substances is 15 years.
  • Page 5: Table Of Contents

    SP-20000M-CXP2 / SP-20000C-CXP-2 Contents Introduction ..................- 6 - General ..................- 7 - Camera composition ..............- 7 - 3. Key features ................- 8 - 4. Parts locations and their functions ........... - 9 - 4.1 Parts locations and their functions................ - 9 - Rear Panel ....................
  • Page 6 SP-20000M-CXP2 / SP-20000C-CXP-2 6.3.4 Mirroring function ................... - 33 - 6.3.5 Multi ROI function ................... - 34 - 6.3.5.1 Multi ROI setting parameters ..............- 34 - 6.3.5.2 Associated GenICam register information ..........- 36 - Digital output bit allocation ................- 36 - Operating modes ..............
  • Page 7 SP-20000M-CXP2 / SP-20000C-CXP-2 8.3.1 LUT Enable .................... - 72 - 8.3.2 LUT Index ..................... - 72 - 8.3.3 LUT Value ..................... - 72 - 8.3.4 Associated GenICam register information ............- 72 - Gamma ...................... - 73 - Shading Correction ..................- 73 - Blemish compensation ...................
  • Page 8: Introduction

    SP-20000M-CXP2 / SP-20000C-CXP-2 Introduction EMVA 1288 With regard to signal to noise ratio in this manual, specifications measured by EMVA 1288 are used together with specifications by a traditional measurement method. EMVA 1288 is a more complete measurement that considers multiple noise sources, including random noise, pattern noise, and shading.
  • Page 9: General

    The SP-20000-CXP2 cameras are members of JAI’s new “Spark Series.” They provide both high resolution and a high frame rate with excellent image quality for machine vision applications. The SP-20000M-CXP2 is a monochrome progressive scan COMS camera and the SP-20000C-CXP2 is the equivalent Bayer mosaic progressive scan CMOS camera.
  • Page 10: Key Features

    SP-20000M-CXP2 / SP-20000C-CXP-2 3. Key features  New Spark Series, 35mm full size, CMOS 20-megapixel progressive scan camera with global shutter  Utilizes CoaXPress interface with two cables configuration  Aspect ratio 4:3, 5120(H) x 3480(V) - 20 million effective pixels ...
  • Page 11: Parts Locations And Their Functions

    SP-20000M-CXP2 / SP-20000C-CXP-2 4. Parts locations and their functions 4.1 Parts locations and their functions  Lens mount F-mount (Note *1)  AUX 10-pin connector AUX Connector for TTL IN/OUT and LVDS IN  LED Indication for power and trigger input ...
  • Page 12: Rear Panel

    SP-20000M-CXP2 / SP-20000C-CXP-2 Rear Panel The rear panel mounted LED provides the following information: POWER/ T RIG Amber: Power connected – initiating  This light goes OFF after initiating. D C IN /TRIG In the process of changing Link Configuration Steady green: Camera is operating in Continuous mode ...
  • Page 13: Input And Output

    SP-20000M-CXP2 / SP-20000C-CXP-2 5. Input and output CoaXPress interface standard The SP-20000-CXP2 use CoaXPress as their interface. CoaXPress is a PLUG-AND-PLAY interface and connects the camera and the frame grabber board by coaxial cable(s). Its maximum transfer rate is 6.25 Gbps per one coaxial cable.
  • Page 14: Connectors And Pin Assignment

    SP-20000M-CXP2 / SP-20000C-CXP-2 Connectors and pin assignment 5.2.1 Digital Video Output (75Ω 1.0・2.3 DIN Receptacle) Type: CoaXPress Connector (ACX1785-ND Amphenol Connector or equivalent) CXP#1 PoCXP compliant CXP#2 Maximum Bit Rate per one coax: 6.25 Gbps Maximum Bit Rate per two coax: 12.5 Gbps Note: If one coaxial cable is used, CXP#1 must be used.
  • Page 15: Aux Connector Hirose 10-Pin Connector

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.2.3 AUX Connector Hirose 10-Pin connector Type: HIROSE 10-Pin Connector 3260-10S3(55) Fig. 4 Hirose 10p connector Table-3 Pin configuration for Hirose 10P Name Note Line8 TTL OUT2 Line9 TTL OUT3 Line10 TTL IN2 LVDS IN1+ Line11 LVDS IN1-...
  • Page 16: Line Source

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.3.2 Line Source Line source signal can be selected from the following table to connect it to the line item which is selected in the line selector. Table-5 Line Source Line Source item Description Connect Low Level signal to line item selected in Line Selector, Default setting...
  • Page 17: Line Mode

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.3.3 Line Mode Indicates the status of the item selected in Line Selector. (INPUT or OUTPUT) Table – 6 Associated GenICam register information GenICam Name Access Values Category Line1,2,4,5,7~11 Line Selector Digital I/O Control NAND 0 In1 to 2...
  • Page 18: Gpio

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.3.7 GPIO GPIO is a general interface for input and output and controls the I/O for trigger signals and other valid signals and pulse generators. By using this interface you can control an external light source, make a delay function for an external trigger signal, or make a precise exposure setting together with a PWC trigger.
  • Page 19: Input And Output Matrix Table

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.3.7.2 Input and output matrix table The relation between input and output is as follows. Table - 7 GPIO matrix table Selector (Cross Trigger Pulse Generator Line Selector point switch output) Selector Selector Source signal (Cross point switch input) ...
  • Page 20: 5.4 Optical Interface

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.4 Optical Interface SP-20000-CXP2 is equipped with opto-isolated inputs and outputs, providing galvanic separation between the camera’s inputs/outputs and peripheral equipment. In addition to galvanic separation, the opto-isolated inputs and outputs can cope with a wide range of voltages;...
  • Page 21: Characteristics Of Optical Interface

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.4.3 Characteristics of optical interface The relationship of the input signal to the output signal through the optical interface is as follows. User Power(VCC) SP-20000 270Ω User 3.3V Power Output line 270Ω Time Delay Rise TDR (us) 0.54...
  • Page 22: Clock Pre-Scaler

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.5.1 Clock Pre-scaler Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit length) and the sensor clock is used for this. Four built-in pulse generators work by the same clock. In the SP-20000-PMCL, the sensor pixel clock is 40 MHz .
  • Page 23: Pulse Generator End Point

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.5.5 Pulse Generator End Point Set the active output ending count value for the selected pulse generator. 5.5.6 Pulse Generator Repeat Count Set the repeating number of the pulse for the selected pulse generator. After Trigger Clear signal is input, the pulse generator starts the count set in Repeat Count.
  • Page 24: Pulse Generator Clear Source

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.5.9 Pulse Generator Clear Source The following clear source can be selected as the pulse generator clear signal. Tabel - 10 Pulse generator clear source Pulse Generator Clear Source Description item Connect Low level signal to Clear Source for the selected pulse generator.
  • Page 25: Pulse Generator Inverter

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.5.10 Pulse Generator Inverter Clear Source Signal can have polarity inverted. 5.5.11 Pulse Generator setting parameters Table - 11 Pulse Generator setting parameters Display Name Value Clock Pre-scaler 1 to 4096 Pulse Generator Clock (MHz) [Pixel Clock: 40 MHz ]÷[Clock Pre-scaler]...
  • Page 26: Associated Genicam Register Information

    SP-20000M-CXP2 / SP-20000C-CXP-2 5.5.12 Associated GenICam register information Table – 12 Associated GenICam register information GenICam Name Access Values Category Pre-scaler 1 to 4096 Pulse Generators Pulse Generator PG0 to PG3 Pulse Generators Selector Pulse Generator 0 to 1048575 Pulse Generators...
  • Page 27: Sensor Layout, Output Format And Timing

    SP-20000M-CXP2 / SP-20000C-CXP-2 Sensor layout, output format and timing Sensor layout The CMOS sensors used in the SP-20000-CXP2 have the following pixel layout. 6.1.1 Monochrome sensor Pixel (0,0) 5120 Pixels Fig. 13 Monochrome sensorlayout 6.1.2 Bayer sensor Pixel (0,0) 5120 Pixels Fig.
  • Page 28: Camera Output Format (Tap Geometry)

    SP-20000M-CXP2 / SP-20000C-CXP-2 Camera output format (Tap Geometry) Table - 13 Output format Camera output format Pixel format Refer to drawing 1X–1Y 8-bit, 10-bit, 12-bit, RGB 8-bit 6.2.1 Note: The camera output description is based on GenICam SFNC Ver.1.5.1. 6.2.1 1X–1Y...
  • Page 29: Output Timing And Output Image

    The horizontal frequency depends on the link configuration. The following chart and tables explains the details. In the SP-20000M-CXP2, the horizontal frequency does not change when horizontal binning is effective, and therefore, the frame rate is not increased. FVAL Active...
  • Page 30 SP-20000M-CXP2 / SP-20000C-CXP-2 Table – 14 Horizontal format in continuous trigger (1/2) Camera Settings Exposure Step LVAL LVAL H-Offset Active Start (Typ. Active Non-Active Binning LVAL Active Start [Unit: [Unit: [Unit: [Unit: us] Clock] Clock] Clock] 5120 3840 0.512 (Off)
  • Page 31 SP-20000M-CXP2 / SP-20000C-CXP-2 Table – 15 Horizontal format in continuous trigger (2/2) Camera Settings 1Line Binning Horizontal Horizontal Total Frequency Period Clock [Unit: Clock] [Unit: kHz] [Unit: us] 5120 3840 (Off 320.5 124.805 8.013 (Off) 5120 1920 (Off 62.402 16.025...
  • Page 32: Vertical Timing

    SP-20000M-CXP2 / SP-20000C-CXP-2 6.3.2 Vertical timing In Continuous Trigger operation, the output timing relation is as follows. The SP-20000M-CXP2 supports H-Binning and V-Binning functions, but the frame rate is not increased. FVAL Active (A) FVAL Active (A) Internal FVAL Internal FVAL...
  • Page 33: Roi (Region Of Interest)

    SP-20000M-CXP2 / SP-20000C-CXP-2 Table – 17 Vertical format in Continuous Trigger (2/2) Camera Settings Binning Exposure 1:OFF, 2:ON Exposure Frame Time Rate FVAL (Max.) Active Start [Unit: [Unit: Hz] [Unit: us] [Unit: us] Line] 5120 3840 38.1 305.225 [Acquisition Frame Rate...
  • Page 34 SP-20000M-CXP2 / SP-20000C-CXP-2 Setting example (2) Readout area Binning Horizontal = 2 Binning Vertical Width OffsetX Mirroring = Off OffsetY Height 2560 Width Max Note: Binning is available only for SP-20000M-CXP2. Binning can be used in horizontal, vertical, or both directions.
  • Page 35: Mirroring Function

    SP-20000M-CXP2 / SP-20000C-CXP-2 6.3.4 Mirroring function SP-20000-CXP2 has the ability to reverse the image vertically, horizontally, or both vertically and horizontally. If ROI readout is used, ROI image can be read out after the image is reversed. The following drawings are setting examples of mirror image.
  • Page 36: Multi Roi Function

    SP-20000M-CXP2 / SP-20000C-CXP-2 6.3.5 Multi ROI function This function divides one frame image into a maximum of 8 images vertically and reads out all areas in one frame. In this function, width is the same for all 8 images. The multi ROI function is enabled if [Video Sending Mode] is set to “Multi ROI”.
  • Page 37 SP-20000M-CXP2 / SP-20000C-CXP-2 ROI setting explanation if Multi ROI Index Max is set to 4 Index 4 Offset X Index 2 Offset X Index 1 Offset X Index 3 Offset X Index 1 Offset Y Index 1 Height Index 2...
  • Page 38: Associated Genicam Register Information

    SP-20000M-CXP2 / SP-20000C-CXP-2 6.3.5.2 Associated GenICam register information Table – 21 Associated GenICam register information GenICam Name Access Values Category Normal Mode Trigger Sequence Video Send Mode Selector JAI-Custom Command Sequence Multi Mode Multi ROI Index Index 0 to Index 7...
  • Page 39: Operating Modes

    SP-20000M-CXP2 / SP-20000C-CXP-2 Operating modes 7.1. Acquisition control (change the frame rate) 7.1.1 Acquisition control With Trigger OFF and in free-running mode, the default frame rate of the camera is based on the specified ROI. The smaller the ROI, the faster the default frame rate. However, it is possible to specify a free-running frame rate that is slower than the default rate.
  • Page 40: 7.1.3 Calculation Of Frame Rate(In Continuous Trigger Mode

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.1.3 Calculation of frame rate(In Continuous Trigger mode) Table – 24 Calculation of frame rate Camera Settings Acquisiton Frame Rate Minimum Value setting formula Link Sensor Binning [Unit:us] Configuration Clock Vertical CXP6_X2 40MHz 1 (Off) ROUNDDOWN((([Height] x 320.5) + 102600 ) ÷ 40MHz x...
  • Page 41 SP-20000M-CXP2 / SP-20000C-CXP-2 For trigger operation, Exposure Mode must be set to something other than OFF and Trigger Mode of Frame Start must be ON. If Exposure Mode is set at Timed, the exposure operation can be selected as follows by setting Trigger Option Table –...
  • Page 42: Exposuretime

    8 secs of exposure time. SP-20000M-CXP2: Up to 15 ºC of ambient temperature SP-20000C-CXP2: Up to 5ºC of ambient temperature Table – 30...
  • Page 43 SP-20000M-CXP2 / SP-20000C-CXP-2 Table – 31 Modes where the exposure control becomes 1L if overlap occurs JAI Custom Naming Trigger Mode Trigger Overlap Continuous Trigger (don't care) EPS Trigger / LVAL SYNC Reset Readout Off / On Readout, if the trigger mode is ON.
  • Page 44: Exposureauto

    SP-20000M-CXP2 / SP-20000C-CXP-2 Extended figure(1) In overlap condition, the At exposure start exposure start timing is changed by 1 LVAL unit. side Exposure Timing Internal LVAL Continuous Trigger operation, if the exposure time increased, “Active” Internal FVAL exposure start point will be increased 1 line step.
  • Page 45: Trigger Operation

    SP-20000M-CXP2 / SP-20000C-CXP-2 Table – 33 Associated GenICam register information GenICam Name Access Values Category Exposure Auto Continuous Acquisition Control Once Exposure Auto Max 100 to 8000000 JAI-Custom Exposure Auto Min 100 to 8000000 JAI-Custom 7.3. Trigger operation Trigger Source can be selected in Trigger Selector.
  • Page 46: Triggersource

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.3.3 TriggerSource Select the trigger source to be used for trigger operation from the following table. Table – 36 Trigger Source Trigger Source Item Description Connect LOW level signal to the selected trigger operation Default setting High...
  • Page 47: Triggeroverlap

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.3.5 Triggeroverlap This function defines whether or not a trigger pulse can be accepted while data is being read out. OFF: The trigger pulse is not accepted during CMOS readout. Read Out: The trigger pulse can be accepted during CMOS readout.
  • Page 48: Normal Continuous Operation (Timed Exposure Mode/Trigger Mode Off)

    133.333 ms (Note2) Note 1: Readout setting in Trigger Overlap is not available Note 2: SP-20000M-CXP2 only 7.5. Timed mode (EPS) This mode allows a single image frame to be captured with a preset exposure time by using the external trigger.
  • Page 49: If Overlap Setting Is Off

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.5.1 If Overlap setting is OFF Frame Start Trigger Frame Trigger Wait Frame Active CMOS Exposure Exposure Active Exposure Period FVAL Note Note: The trigger pulse is accepted during Frame Trigger Wait being active if the trigger overlap is OFF.
  • Page 50: If Overlap Setting Is Readout

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.5.2 If Overlap setting is Readout Frame Start Trigger Frame Trigger Wait Frame Active CMOS Exposure Exposure Active Exposure Period FVAL Read out by previous trigger Note Note: If the trigger overlap is Readout mode, Frame Trigger Wait is active on FVAL period of the previous trigger.
  • Page 51 SP-20000M-CXP2 / SP-20000C-CXP-2 Table – 44 Minimum trigger interval calculation formula (Trigger Overlap: Readout) Camera Settings Conditions: Trigger Mode=“On”,Exposure Mode=“Timed”,Trigger Overlap=“Readout” Link Binning [Unit:us] Configurati Geometr Vertical CXP6_X2 1X – 1Y 1 (Off) If ROUNDDOWN(((([Height]+1) x 320.5) + 12205 ) ÷ 40MHz x 10^6) + 10 - 260 ≧...
  • Page 52: Gpio Ttl Output Timing If Trigger Overlap Is Off

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.5.3 GPIO TTL output timing if Trigger Overlap is OFF Frame Start -Trigger Mode =“On” Exposure Mode =“Timed” Trigger Overlap =OFF Frame Start Trigger Frame Trigger Wait Frame Active Exposure Active FVAL Active Fig. 28 GPIO TTL OUT timing...
  • Page 53: Gpio Ttl Output Timing If Trigger Overlap Is Readout

    SP-20000M-CXP2 / SP-20000C-CXP-2 7.5.4 GPIO TTL output timing if Trigger Overlap is Readout Frame Start -Trigger Mode =“On” Exposure Mode =“Timed” Trigger Overlap =“Readout” Frame Start Trigger Starting position of Frame Trigger Active at EPS Trigger Frame / [Trigger Overlap] = “Readout” setting.
  • Page 54: Trigger Width Mode (Pwc)

    SP-20000M-CXP2 / SP-20000C-CXP2 Trigger width mode (PWC) In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer exposure times are supported. Additional settings determine if the trigger pulse can be accepted during the exposure period.
  • Page 55: If Overlap Setting Is Off

    SP-20000M-CXP2 / SP-20000C-CXP2 7.6.1 If Overlap setting is OFF Frame Start Trigger Frame Trigger Wait Frame Active CMOS Exposure Exposure Active Exposure Period FVAL Note Note: The trigger pulse is accepted during Frame Trigger Wait being active if the trigger overlap is OFF. When the trigger is accepted, the trigger wait is inactive until the readout is completed.
  • Page 56: If Overlap Setting Is Readout

    SP-20000M-CXP2 / SP-20000C-CXP2 7.6.2 If Overlap setting is Readout Frame Start Trigger Frame Trigger Wait Frame Active CMOS Exposure Exposure Active Exposure Period FVAL Read out by previous trigger Note Note: If the trigger overlap is Readout mode, Frame Trigger Wait is active during FVAL period of the previous trigger.
  • Page 57: Minimum Trigger Interval Calculation Formula (Trigger Overlap = Off)

    SP-20000M-CXP2 / SP-20000C-CXP2 7.6.3 Minimum trigger interval calculation formula (Trigger Overlap = OFF) Table – 48 Minimum trigger interval calculation formula (Trigger Overlap = OFF) Camera Settings Conditions: PWC Trigger / Trigger Overlap = OFF Link Binning [Unit:us] Configuration Geometry...
  • Page 58: Minimum Trigger Interval Calculation Formula (Trigger Overlap = Readout)

    SP-20000M-CXP2 / SP-20000C-CXP2 7.6.4 Minimum trigger interval calculation formula (Trigger Overlap = Readout) Table – 49 Minimum trigger interval calculation formula (Trigger Overlap = Readout) Camera Settings Conditions: PWC Trigger / Trigger Overlap = Readout Binning Link Vertical [Unit:us] Configuration...
  • Page 59: Piv (Particle Image Velocimetry)

    V Binning ON (Full) ≧63.635 ms ≧126.504 ms ≧252.868 ms (Note2) Note 1. This is Trigegr Overlap=OFF. Trigegr Overlap mode=Readout is not available Note 2. SP-20000M-CXP2 only Trigger Period (Min.) Frame Start Trigger IN Frame Trigger Wait Frame Active Exposure Timing...
  • Page 60 SP-20000M-CXP2 / SP-20000C-CXP2 Table – 51 PIV trigger mode specifications (CXP-6_X2) time Description Exposure Time name Active Geometry_1X_1Y Signal CXP6_X2 Source Exposure Beginning TTL Out 2.11 us delay Internal 400 ns~ 430 ns First exposure time 10us ~ ≒1 Frame ([Height]=3840:33083us Max) period =...
  • Page 61 SP-20000M-CXP2 / SP-20000C-CXP2 Table - 52 PIV trigger mode specifications (CXP-6_X1, CXP3_X2) time Description Exposure Time name Active Geometry_1X_1Y Signal CXP-6_X1 Source CXP-3_X2 Exposure Beginning TTL Out 2.11 us delay Internal 400 ns~ 430 ns First exposure time 10us ~ ≒1 Frame ([Height]=3840:66417us Max) period =...
  • Page 62 SP-20000M-CXP2 / SP-20000C-CXP2 Table - 53 PIV trigger mode specifications (CXP3_X1) time Description Exposure Time name Active Geometry_1X_1Y Signal CXP3_X1 Source Exposure Beginning TTL Out 2.29 us delay Internal 600 ns~ 650 ns First exposure time 10us ~ ≒1 Frame ([Height]=3840:132833us Max) period =...
  • Page 63: Sequence Roi Trigger

    SP-20000M-CXP2 / SP-20000C-CXP2 Sequence ROI Trigger This is a function to capture images in sequence based on preset ROI, Exposure Time, Gain and other parameters in the sequence index table. Basic settings to use this mode Acquisition mode : Continuous...
  • Page 64: Typical Minimum Trigger Interval Of Sequence Roi Trigger

    Note 1. Overlap mode=Readout is not available. Please set the exposure time not to be Readout mode. Note 2. SP-20000M-CXP2 only Note 3. The minimum interval calculation assumes that the exposure time for all sequences are equal. If there are differences, it is necessary to add the diference to the calculation.
  • Page 65 In Sequence ROI Gain Selector, the gain settings for each index are available. SP-20000C-CXP2: Gain (ALL), Red, and Blue can be set. SP-20000M-CXP2: Only Gain is displayed and can be set. (7) Sequence ROI Black Level Black Level setting is available for each index.
  • Page 66 SP-20000M-CXP2 / SP-20000C-CXP2 “TL Params Locked = 1” “Acquisition Stop” “TL Params Locked = 1” “Acquisition Start” “TL Params Locked = 0” “Acquisition Start” “Acquisition Start” Acquisition “Active” “Non-Active” “Active” “Non-Active” “Active” “Non-Active” Active Sequence Index Sequence Index cannot be changed...
  • Page 67 SP-20000M-CXP2 / SP-20000C-CXP2 Acquisition Start Set “Index 0” Trigger In No Input Input Execute Index Table [Sequence ROI Frame Count] Decrement value : -1 >≠ 0 [Sequence Frame Count] Decrement value If Next Index does “Off” have setting, the current...
  • Page 68 SP-20000M-CXP2 / SP-20000C-CXP2 (15) Next Sequence Index If Command Sequence is selected, Next Sequence Index can be used. When the index is changed in the Next Sequence Index selector, a Next Sequence Index command is sent to the camera manually. The index table which is indicated by the Next Sequence Index command is executed by the next trigger input.
  • Page 69: Operation And Function Matrix

    SP-20000M-CXP2 / SP-20000C-CXP2 7.9. Operation and function matrix Table - 46 Operation and function matrix Trigger Trigger Auto Video Send Mode Exposuer Auto White mode Option Auto Trigger Exposure (Note Binning Binning Mode Balance Gain Exposure Overlap Multi control Sequence...
  • Page 70: Other Functions

    SP-20000M-CXP2 / SP-20000C-CXP2 Other functions Black level control This function adjusts the setup level. Variable range: -256 to 255 LSB (at 10-bit output) 8.1.1 Black Level Selector The following items can be adjusted. Monochrome: Black Level All Black Level All/ Black Level Red/ Black Level Blue Color: 8.1.2...
  • Page 71: Associated Genicam Register Information

    Analog Control Gain control The SP-20000M-CXP2 can adjust the master gain level (DigitalGainAll) from x1 (0dB) to 16 times (+24dB) using x1 (0dB) as the reference (Factory default). In the SP-20000C-CXP2, the master gain level (DigitalGainAll) can be adjusted from x1 (0dB) to 16 times (+24dB) and R and B gains can be adjusted in the range of 0.45 times (-7dB) to 3.16 times (+ 10dB) using...
  • Page 72: Gain Selector

    SP-20000M-CXP2 / SP-20000C-CXP2 8.2.1 Gain Selector The following parameters can be set. Monochrome: Digital All Color: Digital All / Digital Red/ Digital Blue 8.2.2 Gain The range for adjustment is as follows. Monochrome: Digital All : 100 ~ 1600 (0dB ~24dB) Color: Digital All : 100 ~...
  • Page 73: Associated Genicam Register Information

    SP-20000M-CXP2 / SP-20000C-CXP2 8.2.5 Associated GenICam register information Table – 58 Associated GenICam register information GenICam Name Access Values Category Gain Auto Continuous Analog Control Once ALC Speed 1 to 8 JAI-Custom ALC Reference 1 to 100 JAI-Custom Gain Auto Max...
  • Page 74: Lut

    SP-20000M-CXP2 / SP-20000C-CXP2 8.3. This function can be used to convert the input to the desired output characteristics. The Look-Up Table (LUT) has 256 points for setup. The output level can be created by multiplying the gain data by the input level.
  • Page 75: Gamma

    SP-20000M-CXP2 / SP-20000C-CXP2 Gamma This command is used set gamma between gamma 0.45 and gamma 1.0(OFF). 16 steps are provided. The gamma value is an approximate value. Fig.40 Gamma correction Shading Correction This function compensates for shading (non-uniformity) caused by the lens or the light source used.
  • Page 76: Blemish Compensation

    SP-20000M-CXP2 / SP-20000C-CXP2 Before adjustment After adjustment Fig. 42 Concept drawing of Color shadingcorrection Note: Under the following conditions, the shading correction circuit may not work properly. If there is some area in the image with a video level less than 70% ...
  • Page 77: Alc

    SP-20000M-CXP2 / SP-20000C-CXP2 Avaraging Avaraging Defective pixels Defective pixels Fig. 44 Compensation if defective pixels are in series Table – 61 Associated GenICam register information GenICam Name Access Values Category False Blemish Reduction Enable JAI-Custom True Blemish Reduction Calibration True...
  • Page 78 SP-20000M-CXP2 / SP-20000C-CXP2 Table - -62 Associated GenICam register information GenICamName Access Values Category Exposure Auto Continuous Acquisition Control Once Gain Auto Continuous Analog Control Once ALC Speed 1 to 8 JAI-Custom ALC Reference 1 to 100 JAI-Custom ASC Max...
  • Page 79: Hdr Function (Option)

    SP-20000M-CXP2 / SP-20000C-CXP2 HDR function (Option) The SP-20000M-CXP2 has a High Dynamic Range function which utilizes built-in sensor characteristics. If [Exposure Mode] is set to“Timed”and then [HDR Mode] is set to “On”, the High Dynamic Range function is activated. In this mode, it is possible to determine the input level of knee point(s) by using the exposure time as the reference.
  • Page 80 SP-20000M-CXP2 / SP-20000C-CXP2 Table – 63 HDR function Setting item Setting value Description HDR Mode On / Off If [Exposure Mode] is set to “Timed”, On or OFF [HDR Mode] Exposure Time Determine the exposure time of HDR. [Unit: The knee point on HDR operation can be...
  • Page 81: Camera Settings

    SP-20000M-CXP2 / SP-20000C-CXP2 9. Camera Settings Camera Control Tool In the SP-20000-CXP2, control of all camera functions is done by the JAI SDK and Control Tool software. All controllable camera functions are stored in an XML file inside of the camera. The JAI SDK and Control Tool software can be downloaded from www.jai.com.
  • Page 82: External Appearance And Dimensions

    SP-20000M-CXP2 / SP-20000C-CXP2 External appearance and dimensions Dimensions tolerance : ±0.3mm Unit : mm Fig. 47 Appearance and Dimensions - 80 -...
  • Page 83: Specifications

    SP-20000M-CXP2 / SP-20000C-CXP2 Specifications 11.1. Camera spectral response Fig.48 SP-20000M-CXP2 Spectral response Fig.49 SP-20000C-CXP2 Spectral response (With IR Cut Filter) - 81 -...
  • Page 84: Specification Table

    SP-20000M-CXP2 / SP-20000C-CXP2 11.2. Specification table Specifications SP-20000M-CXP2 SP-20000C-CXP2 Scanning system Progressive scan, 1-tap output Synchronization Internal CoaXPress (JIIA NIF-011-2010 CoaXPress Standard first edition) Interface 6.25 Gbps, 2 Link PoCXP compliance Image sensor (CMV-20000) 35mm Monochrome CMOS 35mm Bayer color CMOS...
  • Page 85 SP-20000M-CXP2 / SP-20000C-CXP2 Line4(TTL 1), Line 5 (Opt In 1), Line 7 (CXP IN), Pulse Generator 0/1/2/3 Trigger input signal Soft Trigger, Line 10 (TTL 2), Line 11 (LVDS) Timed 299 μs (Min) ~ 8 sec. (Max), Step: 1 μs...
  • Page 86: Appendix

    SP-20000M-CXP2 / SP-20000C-CXP2 Appendix 1. Precautions Personnel not trained in dealing with similar electronic devices should not service this camera. The camera contains components sensitive to electrostatic discharge. The handling of these devices should follow the requirements of electrostatic sensitive components.
  • Page 87: Exportation

    5. Exportation When exporting this product, please follow the export regulation of your own country. 6. References 1. This manual and a datasheet for SP-20000M-CXP2 / SP-20000C-CXP2 can be downloaded from www.jai.com 2. Camera control software can be downloaded from www.jai.com...
  • Page 88: Manual Change History

    SP-20000M-CXP2 / SP-20000C-CXP2 Manual change history Date Revision Changes Nov. 2013 New release Jan. 2014 Correct weight and power consumption in the specifications table, Change the description in Sequence ROI trigger mode, Add GenICam register information to relative chapter, Addcautions to sections, 5.2.2.2, 7.1.2 and 8.2, Correct typo...
  • Page 89: User's Record

    SP-20000M-CXP2 / SP-20000C-CXP2 User's Record Camera type: SP-20000M-CXP2 / SP-20000C-CXP2 Revision: …………….. Serial No. …………….. Firmware version. …………….. For camera revision history, please contact your local JAI distributor. User's Mode Settings. User's Modifications. Company and product names mentioned in this manual are trademarks or registered trademarks of their respective owners.

This manual is also suitable for:

Sp-20000c-cxp2

Table of Contents