When Controlling The Exposure Time Using The Pulse Width Of The Trigger Input Signal - IAI GO-2400M-PMCL User Manual

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

5
If necessary, change the [Trigger Source], [Trigger Activation], and [Exposure Auto]
settings.

When controlling the exposure time using the pulse width of the trigger input signal

Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Exposure Mode
1
Set [Exposure Mode] to [Trigger Width] .
When you select [Trigger Width], [Trigger Mode] will automatically be set to [On].
2
Set [Trigger Selector] to [Frame Start].
([Frame Start] is the default setting.)
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.
Item
̶ 20 ̶
Setting value / selectable range
Frame Start
On
Any
Level High (high-level duration), Level Low (low-level
duration)
Trigger Width (control via trigger width)
GO-2400M-PMCL / GO-2400C-PMCL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-2400c-pmclGo series

Table of Contents