Access
Function name
type
User Output
R/W
True, False
Value
e) Analog Control
Gain Selector
R/W
GO-2400M-PMCL: AnalogAll
[Analog All]
GO-2400C-PMCL: AnalogAll
[Analog All]
DigitalRedAll [Digital Red All]
DigitalBlueAll [Digital Blue All]
Gain
R/W
AnalogAll: 1 to 16
DigitalRedAll,
DigitalBlueAll:0.4467 to 5.6235
Gain Auto
R/W
Off
Continuous
Black Level
R/W
GO-2400M-PMCL:
Selector
Digita All [Digital All]
GO-2400C-PMCL:
DigitalAll [Digital All]
DigitalRed [Digital Red]
DigitalBlue [Digital Blue]
Black Level
R/W
–133 to 255
Balance White
R/W
Off [Off]
Auto
Once [Once]
Continuous [Continuous]
Preset_4600K [Preset 4600K]
Preset_5600K [Preset 5600K]
Preset_6500K [Preset 6500K]
LUT Mode
R/W
Off
Gamma
LUT
Gamma Selector
R/W
Gamma_0_45 [0.45]
Gamma_0_6 [0.6]
Gamma_1_0 [1.0]
f) Pulse
Generators
Clock Pre-scaler
R/W
1 to 4096
Pulse Generator
R/W
0.018127 to 74.25
Clock (MHz)
Pulse Generator
R/O
PulseGenerator0 [Pulse
Selector
Generator 0]
Pulse Generator
R/W
1 to 1048575
Length
Pulse Generator
R/W
0.000013468 to 14.1222
Length (ms)
Setting range
Min. value
AnalogAll: 1 to
16
DigitalRedAll:
0.4467
DigitalBlueAll:
0.4467
–133
1
0.018127
1
1.35E-05
̶ 60 ̶
GO-2400M-PMCL / GO-2400C-PMCL
Max. value
Default value
FALSE
Analog All (master gain)
AnalogAll: 16 to
1
16
DigitalRedAll:
5.6235
DigitalBlueAll:
5.6235
Off
Digital All (master black)
255
0
Off
0: 0.45
0: Off
4096
1
74.25
74.25
Pulse Generator 0
1048575
1
14.1222
1.35E-05
Description
Set the User Output
value selected in
[User Output
Selector].
Configure analog
control settings.
Select the gain to
configure.
Digital Red All and
Digital Blue All are
only available on the
GO-2400C-PMCL.
Set the gain value for
the gain item
selected with the
GainSelector setting.
Select the black level
to configure.
Digital Red All and
Digital Blue All are
only available on the
GO-2400C-PMCL.
Set the black level
value.
Enable/disable auto
white balance.
Select the JAI LUT
mode.
Set the gamma value.
Configure pulse
generator settings.
Set the division value
for the prescaler
(12-bit) using the
pixel clock as the
base clock.
Set the clock used for
the pulse generator.
This value is
calculated based on
the Clock Pre-Scaler
value.
Select the pulse
generator.
Set the maximum
count up value using
clock value.
Set the maximum
count up value using
ms.
This value is
calculated based on
the Pulse Generator
Length value.
The setting range
varies depending on
the Clock Pre-Scaler
value.