9. Transport Layer Control
DeviceTapGeometry
R/W
10. User Set Control
UserSetLoad
(R)/W
UserSetSave
(R)/W
11. Counter and Timer Control
Counter0EventSource
R/W
Counter1EventSource
R/W
Counter2EventSource
R/W
Counter0Reset
(R)/W
Counter1Reset
(R)/W
Counter2Reset
(R)/W
Counter0Value
R/O
Counter1Value
R/O
Counter2Value
R/O
12. JAI-Custom
AcquisitionFrame
R/W
Period
BlemishWhiteEnable
R/W
BlemishWhiteDetect
W/O
BlemishWhiteDetect
R/W
Threshold
TAGM
1: Geometry_1X2_1Y
3: Geometry_1X4_1Y
5: Geometry_1X8_1Y
7: Geometry_1X3_1Y
LD
0: Default
1: UserSet1
2: UserSet2
3: UserSet3
SA
1: UserSet1
2: UserSet2
3: UserSet3
CE0
False/True
CE1
False/True
CE2
False/True
CR0
1
CR1
1
CR2
1
CV0
Min to Max
CV1
Min to Max
CV2
Min to Max
AR
Min to Max[us]
BMW
0: False
1: True
BMRCW
1
BMTHW
Min to Max
1
7
5
0
3
0
1
3
1
0
1
0
0
1
0
0
1
0
1
1
1
1
1
1
0
65535
0
0
65535
0
0
65535
0
32764 *
8000000
11961
2
0
1
1
1
1
0
100
10
̶ 73 ̶
GO-2400M-PMCL / GO-2400C-PMCL
TAGM=[Param.]<CR><LF>
Set the
TAGM?<CR><LF>
transmission
method for each
time images are
transmitted from
the device (TAP
structure).
LD=[Param.]<CR><LF>
Load user
LD?<CR><LF>
settings.
SA=[Param.]<CR><LF>
Save the current
SA?<CR><LF>
setting values as
user settings.
CE0=[Param.]<CR><LF>
Select the counter
CE0?<CR><LF>
event signal for
which to read the
count value (for
Counter0).
CE1=[Param.]<CR><LF>
Select the counter
CE1?<CR><LF>
event signal for
which to read the
count value (for
Counter1).
CE2=[Param.]<CR><LF>
Select the counter
CE2?<CR><LF>
event signal for
which to read the
count value (for
Counter2).
CR0=0<CR><LF>
Reset Counter0.
CR1=0<CR><LF>
Reset Counter1.
CR2=0<CR><LF>
Reset Counter2.
CV0?<CR><LF>
Display the
Counter0 value.
CV1?<CR><LF>
Display the
Counter1 value.
CV2?<CR><LF>
Display the
Counter2 value.
AR=[Param.]<CR><LF>
Set the frame
AR?<CR><LF>
rate as a frame
Maximum value is calculated
interval [us].
depending on Height and
Offset Y settings
BMW=[Param.]<CR><LF>
Enable/disable
BMW?<CR><LF>
blemish
correction.
BMRCW=0<CR><LF>
Execute blemish
detection.
BMTHW=[Param.]<CR><LF>
Set the blemish
BMTHW?<CR><LF>
detection
threshold.