Changing the value of [Command Sequence Index] to one of the other predefined indexes causes
that index to be executed in response to subsequent triggers. This mode of operation enables users to
develop applications that continually send new values to [Command Sequence Index] in response to
external factors such as changing light conditions, different types or sizes of objects being inspected,
or other factors. This allows applications to change ROI, exposure, gain, etc., without being restricted
to a predefined pattern.
[Sequence LUT Mode] defines whether Gamma or LUT is to be applied to the sequence. If Gamma
is selected, the Gamma setting defined in the camera's Analog Control section will be applied to all
exposures in the sequence. If LUT is selected, the LUT characteristics defined in Analog Control will
be applied to any index where [Sequence LUT enable] has been set to ON.
[Sequence Index Frame Count], [Sequence ROI Next Index], and [Reset Sequence Index] are not
used in Command Sequence mode and entered values are ignored.
Command Sequence example
User-defined Indexes (up to 128)
ROI
Exposure
Gain
LUT
Binning
Set to
Index1
Command
Sequence
Index
Camera
Triggers
Image
Frames
Index1
Settings Used
Settings
Index1
Index2
ROI
Exposure
Gain
LUT
Binning
Set to
Set to
Set to
Index3
Index1
Index2
Index3
Index1
Settings
Settings
̶ 47 ̶
GO-2400M-PMCL / GO-2400C-PMCL
Index3
ROI
Exposure
Gain
LUT
Binning
Set to
Set to
Index1
Index2
Index2
Index1
Index2
Settings
Settings
Settings