Display The - IAI GO-2400M-PMCL User Manual

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

GpioNand1
R/W
InputSource1
GpioNand1
R/W
InputSource2
GpioNand0
R/W
InputInvert1
GpioNand1
R/W
InputInvert1
GpioNand0
R/W
InputInvert2
GpioNand1
R/W
InputInvert2
LUTSequenceR
R/W
LUTSequenceG
R/W
LUTSequenceB
R/W
BlemishNum
R/O
CameraLinkClock
R/O
Frequency
ND1IN1
0: Low
1: High
3: FrameTriggerWait
4: FrameActive
5: ExposureActive
6: Fval
7: Lval
8: PulseGenerator0
10: UserOutput0
11: UserOutput1
12: TTL_In1(Std Only)
13: CL_CC1_In
15: Nand1
ND1IN2
Same as above.
ND0INV1
0: Non-Inv
1: Inv
ND1INV1
Same as above.
ND0INV2
0: Non-Inv
1: Inv
ND1INV2
Same as above.
LUTSR
Min to Max
LUTSG
Min to Max
LUTSB
Min to Max
BNUM
Min to Max
CLCF
0= 84.85MHz
1= 74.25MHz
2= 37.12MHz
0
6
0
0
6
0
0
1
0
0
1
0
0
1
0
0
1
0
0
4095
0
0
4095
0
0
4095
0
0
255
0
0
2
0
̶ 89 ̶
GO-2400M-PMCL / GO-2400C-PMCL
ND1IN1=[Param.]<CR><LF>
Select the input
ND1IN1?<CR><LF>
source signal for
NAND1 In1.
ND1IN2=[Param.]<CR><LF>
Select the input
ND1IN2?<CR><LF>
source signal for
NAND1 In2.
ND0INV1=[Param.]<CR><LF>
Not required.
ND0INV1?<CR><LF>
LineInverter_
Nand0In1 exists
on 37th line.
ND1INV1=[Param.]<CR><LF>
Not required.
ND1INV1?<CR><LF>
LineInverter_
Nand1In1 exists
on 39th line.
ND0INV2=[Param.]<CR><LF>
Not required.
ND0INV2?<CR><LF>
LineInverter_
Nand0In2 exists
on 38th line.
ND1INV2=[Param.]<CR><LF>
Not required.
ND1INV2?<CR><LF>
LineInverter_
Nand1In2 exists
on 40th line.
LUTSR=[Param.]<CR><LF>
When 256
LUTSR?<CR><LF>
commands are
(Color model only)
sent in
succession, the
LUT curve is
updated (during
WRITE) or the LUT
curve is loaded
sequentially
(during READ).
(Red signal)
LUTSG=[Param.]<CR><LF>
When 256
LUTSG?<CR><LF>
commands are
(Color model only)
sent in
succession, the
LUT curve is
updated (during
WRITE) or the LUT
curve is loaded
sequentially
(during READ).
(Green signal)
LUTSB=[Param.]<CR><LF>
When 256
LUTSB?<CR><LF>
commands are
(Color model only)
sent in
succession, the
LUT curve is
updated (during
WRITE) or the LUT
curve is loaded
sequentially
(during READ).
(Blue signal)
BNUM?<CR><LF>

Display the

number of
correction
blemishes.
CLCF =[Param.]<CR><LF>
Set the Camera
CLCF?<CR><LF>
Link clock.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-2400c-pmclGo series

Table of Contents