Output Filter Box Accessory; Figure 3-21: 7003-424-1 Output Noise Filter Box - California Instruments MX30-1 User Manual

Mx series ac and dc power source series i / series ii
Table of Contents

Advertisement

User Manual – Rev AJ
3.14 Ou
tput Filter Box A
An optional output filter box (P/N 7003-424-1) is available which may be used reduce the
amount of ripple and noise present at the output of the MX30/45-3Pi.
The filter must be connected between the three-phase output of the MX30/45 and the unit under
test. To access the connection terminal blocks, the top cover of the filter case must be removed.
Note: Make sure all power is off when connecting the filter accessory.
The output of the MX30/45 is connected to the input side of the filter. Use terminal blocks TB1A
(phases A and B) and TB1B (phase C and neutral) as indicated in Figure 3-21. The load can be
connected to the load side of the filter box using terminal blocks TB2A and TB2B. Do not swap
phases through the filter.
To compensate for voltage drop across the filter, the external sense connections can be made
at the load (load side of the filter).
Note: The filter box chassis must be connected to earth ground.
It is not recommended to use the ground connection on the MX30//45 itself for this purpose but
rather a ground point at the AC service to the MX30/45.
Dimensions 7003-424-1:
W x L x H Chassis
Feet height:
Strain relief hole size:
72
cces
sory

Figure 3-21: 7003-424-1 Output noise filter box.

12.125 " x 16.125" x 4.125"
0.875
1.5" diameter
California Instruments
308 x 410 x 105 mm
22 mm
38 mm diameter