Mechanical - California Instruments MX30-1 User Manual

Mx series ac and dc power source series i / series ii
Table of Contents

Advertisement

User Manual – Rev AJ
2.1.7 Unit Protection
Input Over current:
Input Over voltage:
Input Over voltage
Transients:
Output Over current:
Output Short Circuit:
Over temperature:

2.2 Mechanical

Parameter
Dimensions:
(for each MX chassis)
Unit Weight:
(for each MX chassis)
Material:
Finish:
Cooling:
Internal Construction:
Rear Panel
Connections:
22
In-line fast acting fuses. Check fuse rating in Service and Maintenance
section. Ratings will depend on AC input configuration settings.
Circuit breaker for LV supply.
Automatic shutdown.
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Adjustable level constant current mode with programmable set point.
Peak and RMS current limit.
Automatic shutdown.
Specification
Height:
50.0"
Width:
28.75"
Depth:
34.5"
Net:
1150 lbs / 522 Kg approximately
Shipping:
1231 lbs / 560 Kg approximately
Steel chassis with aluminum panels and covers.
Light textured painted external surfaces.
Panels semi-gloss polyurethane color no. 26440 (medium gray)
Fan cooled with air intake on the front and exhaust to the rear.
Fans:
6 x 225CFM.
Air displacement
22 Cu Ft/sec. Max.
Modular sub assemblies.
(See section 3 for description of connections)
Cable entry and strain relieve for AC input wiring
Cable entry and strain relieve for output wiring
External sense terminal block (Remote voltage sense)
System interface (2x)
Clock and Lock BNC's (requires -LKM or -LKS options)
RS232, USB, GPIB, LAN (option)
Trigger In BNC
Trigger Out BNC
Function Strobe BNC
Output Status
California Instruments
1270 mm
731 mm
876 mm
MX Series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents