7.4 Advanced Troubleshooting.

WARNING:
be a severely damaged unit.
CAUTION:
CERTAIN SECTIONS OF THIS POWER SOURCE.
WARNING:
VOLTAGES. DEATH ON CONTACT MAY RESULT IF PERSONNEL FAIL TO
OBSERVE SAFETY PRECAUTIONS. DO NOT TOUCH ELECTRONIC CIRCUITS
WHEN POWER IS APPLIED
7.4.1 Switch Off Unit
Switch off the unit at the circuit breaker on the front panel as well as removing the input power
from the unit.
WARNING:
7.4.2 Removing Covers
Remove the screws securing the front cover and remove it.
Remove the screws securing the top cover and remove it.
7.4.3 In
itial Inspection
Make a visual inspection of the unit and ensure all the connectors are properly mated and there
are no loose wires.
7.4.4 F
use Check
Using an ohmmeter, check input fuses F1, F2 and F3 for continuity.
178
Do not connect 400-480V into the 208-240V unit, the result could
VOLTAGES UP TO 480 VAC AND 450 VDC ARE PRESENT IN
THIS EQUIPMENT GENERATES POTENTIALLY LETHAL
Wait 10 minutes for all internal capacitors to discharge.
California Instruments