9.5.4.3 RUNNING THE TEST
The test seq
uence used is a function of the EUT class. The end user needs to determine the
appropriate
class of EUT. The test protocol is document in the IEC 61000-4-13 test standard.
For reference, the test flow charts are shown here. It is assumed that the end user has a copy of
the actual test standard however.
Start - Class 1/2
Determine appropriate test
conf
iguration
Perform
8.2.1 Test
"Harmonic
combination"
Flatcurve and Overswing
Any functional
anomalies?
Yes
Test Completed
FAIL
R
ecord Results
220
No
Class 2
required?
No
Perform 8.2.2 Test
"Frequency Sweep"
Any functional
Perform 8.2.3 Test
"Individual Harmonics/
Interharmonics"
Yes
Any functional
Figure 9-2
8: IEC 61000-4-13 Test Flowchart Class 1 and 2
'Meister
Yes
curve' req
uired?
No
anomalies?
No
Yes
Yes
No
anomalies?
California Instruments
Yes
Perform 8.2.4 Test
"Meister Curve"
Any functional
anomalies?
No
Test Completed
PASS
Record Results