Figure 9-20: Application Setup Menus; Figure 9-21: Iec1000-4-13 Menu - California Instruments MX30-1 User Manual

Mx series ac and dc power source series i / series ii
Table of Contents

Advertisement

User Manual - Rev AJ
9.5.4 F
ron
t Pa
nel Entry
While it
is possible to perform IEC 61000-4-13 testing from the front panel of the MX Series
power source, it is recommended to use the provided MXGui Windows program for report
generation. This also provides a more convenient way to perform Class 1 and User class tests
as test l
evels can be saved to disk.
To perfo
rm a test from the keyboard, select the APP
screen. The APPLICATIONS SETUP 1 screen will appear. Move to the MORE field to proceed
to the APPLICATIONS SETUP 2 screen as shown in Figure 9-20. (Note: On Series I MX
models, the IEC 1000-4-13 option is located on the APPLICATIONS SETUP screen instead as
there is only one APPLICATIONS SETUP screen.)
Scroll to the IEC 1000-4-13 entry using the up and down cursor keys. Press the ENTER key to
select the IEC 1000-4-13 main menu. The screen will appear as shown in Figure 9-21.
9.5.4.1 IEC Screen Parameters
The IEC 1000-4-13 has the following common fields for all IEC1000-4-13 test groups.
STATE
The STATE field must be set to ON before the test can run. Initial setup conditions must be met
to run the test. See section 9.5.2.
RUN
The RUN field has the following selections:
1. ALL Run all IEC 1000-4-13.
2. GROUP
3. RANGE
4. POINT
Note: The RANGE and POINT do not apply to all groups. See individual groups for details.
When the test is running, this field will have the following selection:
1. ABORT
2. PAUSE
pressed again, the test will resume from the point it stopped.
214

Figure 9-20: Application Setup Menus

Figure 9-21: IEC1000-4-13 Menu

Run the selected group.
Run the selected range for the selected group.
Run the selected frequency for the selected range and selected group.
The test will stop running and all parameters will return to the state prior to the
start of the test.
The test will pause at the time the ENTER key is pressed while the PAUSE field
is selected. The field will change to RESUME. When the ENTER key is
California Instruments
LICATIONS screen from the MENU 2