3.9 Multiple Cabinet Power Up/Down Procedures

For all multi-cabinet MX Series configurations (MX60, MX90, MX135, MX180, MX225 and
MX270), the following Power Up (Turn on) and Power Down (Turn off) procedures should be
observed.
3.9.1 P
ower Up Procedure
Follow these steps:
1. Turn on each of the Auxiliary units using the front panel circuit breaker, one at a time.
The exact order for turning on the auxiliary units is not important. Note that the bias
supplies of each of the auxiliary cabinets
is because the auxiliary units are waiting for the turn on signal from the master unit.
2. Once all auxiliary units are on,
circuit breaker. The master unit will go through an initialization process and power up
itself plus the auxiliary units.
3. Allow 20 to 30 seconds for the turn on sequence to complete before attempting to
communicate with the system.
3.9.2 P
ower Down Procedure
Th
e power-down / shutd
sequence. This means the MASTER
all auxiliary units' main AC input power contactors will open up automatically. They still need to
be turned off individually using the front panel ci
supplies as well.
Follow these steps:
1. Disconnect the EUT
the master unit front panel or send the "
2. Turn off the MASTER unit FIRST using the front panel circuit breaker. The master unit
will disengage the main AC power input contactors of all auxiliary units at this time.
3. Next, turn off each of the Auxiliary units using the front panel circuit breaker, one at a
time. The exact order for turning off the auxiliary units is not important.
MX Series
turn on the MASTER unit LAST using the front panel
ow
n sequence f
or the s
unit is turned off FIRST. Once the MASTER shuts down,
by
opening the MX
will power up but not the actual amplifiers. This
ystem is the re
verse of the power-up / turn-on
rcuit breaker. This will shut down their bias
output relay. Use the Output On/Off button o
OUTPUT 0" command over the bus to do so.