2.7 Supplemental Specifications

Supplemental specifications are not warranted and generally reflect typical performance
characteristics. These characteristics are have been checked on a type test basis only and are
not verified on each unit shipped. They are provided for reference only.
2.7.1 Output
Output Parameter
Voltage:
Slew rate:
Stability:
Settling time:
Frequency:
Temperature
coefficient:
Stability:
Current:
Constant Power
Mode:
2.7.2 Acoustic Noise Levels
Acoustic Noise:
Front
Back
MX Series
MX30
MX45
> 0.5 V/micro sec
0.25 % over 24 hour period at constant line, load and temperature.
< 0.5 msec
± 5ppm per degree C
± 15 ppm per year
Operation at higher currents but constant power is possible from 80% of
Voltage range (125% of max. current) declining to 100% of maximum current
at 100 % of voltage range for short periods of time or at reduced ambient
temperatures. (< 15 mins @ 30° C). See Figure 2-3 and Figure 2-4.
Note: This mode requires firmware revision 0.27 or higher.
Measured at a distance of one meter. (3 ft.)
63 dBA at no load to 68 dBA at full load.
65 dBA at no load to 72 dBA at full load