CHAPTER 1: SPECIFICATIONS
Electrostatic Discharge
RF immunity
Fast Transient Disturbance
Surge Immunity
Conducted RF Immunity
Power magnetic Immunity
Damped magnetic Immunity
Voltage Dip & interruption
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
PACKAGING
Enclosure: ................................... High strength Cold rolled steel
Dimensions: .............................. 8.0 in H x 1.75 in W x 6.0 in D (in vertical mounting position)
............................... 20.3 cm H x 4.4 cm W x 15.2 cm D
Cooling method: ........................ Convection, fully-enclosed steel case used as a heat sink; designed
Weight: .......................................... 2.1 lbs. (0.95 kg)
DC POWER SUPPLY (INTERNAL, FLOATING GROUND)
DC Power Connector: ............. Terminal block
12VDC Power Input nominal (range 10 to 15VDC)
24VDC Power Input nominal (range 18 to 36VDC)
48VDC Power Input nominal (range 36 to 60VDC)
Std. Terminal Block: ................. "-GND, +"
Power Input for PoE: ................ add up to 15 watts per PoE port to the base unit power draw
DC POWER SUPPLY (INTERNAL, FLOATING GROUND)
DC Power Connector: ............. IEC-320 type, male recessed from cord exiting unit
125VDC Power Input nominal (range 88 to 150VDC)
250VDC Power Input nominal (range 160 to 300VDC)
AC POWER SUPPLY (INTERNAL)
AC Power Connector: ............. IEC-320 type, male recessed
100-240VAC Power Input, 47 to 63 Hz (auto-ranging)
POWER CONSUMPTION
15 watts Max. (for a fully loaded fiber model with 2Gb)
10 watts Max. (for 8 port copper and 100Mb fiber model)
DUAL DC POWER INPUT (OPTIONAL)
A Dual-Source option is available for the 12VDC, 24VDC, –48VDC, and 125VDC and 250VDC
models. This provides for continuity of operation when either of the DC input sources is
interrupted. See Appendices B and C.
The Dual-Source Terminal Block is marked: "+A, -A, -B, +B"
MANAGEMENT CONSOLE CONNECTOR
RJ45, see details at sec. 3.6
ML810 MOUNTING
Vertical mounting normal. Suitable for wall or DIN-Rail mounting
TYPE TESTS
TEST
for vertical mounting, no fans
REFERENCE STANDARD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
IEC61000-4-8
IEC61000-4-10
IEC61000-4-11
TECHNICAL SPECIFICATIONS
TEST LEVEL
Level 4
Level 3
Level 3 & 4
Level 3 & 4
Level 3
Level 3
Level 3
0,40,70% dips, 300cycle
interrupts
1–3