SYSTEM CONFIGURATION
[SYSTEM]
***Edit below this line only***
system_name=ML810
system_contact=support@gemultilin.com
system_location= Markham, Ontario
boot_mode=manual
system_ip=192.168.5.5
system_subnet=0.0.0.0
system_gateway=0.0.0.0
idle_timeout=10
telnet_access=enable
snmp_access=enable
web_access=enable
***Edit above this line only***
##########################################################
# User Accounts - This area configures user accounts for #
#
##########################################################
...
Note
NOTE
5–16
accessing this system.
1.
A config file allows only certain portions of the file to be edited by a user. Changing
any other part of the file will result in the system not allowing the file to be loaded, as
the CRC computed and stored in the file would not be matched. Should you want to
edit, edit the System portion of the file only. GE Digital Energy, Inc. recommends
editing the "script" file (see below)
2.
File names cannot have special characters such as *#!@$^&* space and control
characters.
#
FIGURE 5–1: Contents of a config file
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
CHAPTER 5: IP ADDRESSING
Need help?
Do you have a question about the Multilink ML810 and is the answer not in the manual?