17.1.2 Commands

17–2
• User can defined a global default SMTP server identified by its IP address, TCP port
and retry count.
• User can add up to five SMTP alert recipients. Each recipient is identified by an ID
and e-mail address. The e-mail address needs to be a valid address and can be an
alias setup for distribution to a larger audience.
• Filters are provided for each recipient to allow only certain categories of traps and
events be sent by e-mail.
• Each recipient can have its own SMTP server and TCP port number, if this is not
defined on a certain recipient, the default SMTP server and TCP port number is
used.
The
command configures the SNMP alerts to be sent via e-mail.
smtp
smtp
smtp <enable|disable>
The
command displays the current SMTP global settings and recipients
show smtp
displays the currently configured recipients of e-mail alerts.
show smtp <config|recipients>
The
command adds a specific
add
ranges from 1 to 5. The software allows a maximum of 5 recipients
add id=<1-5> email=<email-addr> [traps=<all|none|S|R|E>]
[events=<all|none|I|A|C|F|D>] [ip=<ip-addr>] [port=<1-65535>] [domain=<domain>]
The
command has the following additional parameters:
add
• The
parameter is the e-mail address of the recipient.
email
• The optional
traps
any type will be sent to this recipient. If value is none, no traps are sent to this
recipient. Value can also be a combination of 'S' (SNMP), 'R' (RMON) and 'E'
(enterprise). For example,
via e-mail to the recipient. If this option is not defined, the recipient will have a
default value of "all".
• The optional
events
severity types will be sent to recipient, "none" - no event will be sent to recipient or
a combination of 'I' (informational), 'A' (activity), 'C' (critical), 'F' (fatal) and 'D' (debug).
With "
" implies that events of severity types activity, critical and fatal will
event=ACF
be sent to recipients by e-mail. If this option is not defined, a value of "all" is taken.
• The optional
parameter represents the SMTP server IP address. This is the SMTP
ip
server to connect to for this particular user. If this option is not defined, the global/
default SMTP server is used.
• The optional
port
defined, the global default TCP port is used.
The
parameter specifies the domain name of the SMTP server. If this
optional domain
is not defined, the global default domain name is used.
The
command deletes the specific
delete
the traps via e-mail. The
id
delete id=<1-5>
CHAPTER 17: MISCELLANEOUS COMMANDS
, where
represents the recipient identification and
id
id
parameter represents the trap filter. If value is all, all traps of
means that SNMP and RMON traps will be sent
trap=SR
parameter is the event filter. Value can be "all" - all event
parameter specifies the TCP port of the SMTP server. If this is not
specified. The deleted
id
is added using the
command
add
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
no longer receives
id

Hide quick links: