TECHNICAL SPECIFICATIONS
1–2
MAXIMUM 10 MBPS ETHERNET SEGMENT LENGTHS
Unshielded twisted pair: ........ 100 m (328 ft)
Shielded twisted pair:.............. 150 m (492 ft)
10BASE-FL multi-mode fiber optic:2 km (6,562 ft)
10BASE-FL single-mode fiber optic:10 km (32,810 ft)
MAXIMUM STANDARD FAST ETHERNET SEGMENT LENGTHS:
10BASE-T (CAT 3, 4, 5 UTP)..... 100 m (328 ft)
100BASE-TX (CAT 5 UTP)......... 100 m (328 ft)
Shielded twisted pair ............... 150 m (492 ft)
100BASE-FX, half-duplex, multi-mode412 m (1350 ft)
100BASE-FX, full-duplex, multi-mode2.0 km (6,562 ft)
100BASE-FX, half-duplex, single-mode412 m (1350 ft)
100BASE-FX, full-duplex, single-mode20.0 km (66K ft)
100BASE-FX, full-duplex, Long Reach40.0 km (122K ft)
MAXIMUM STANDARD GIGABIT ETHERNET SEGMENT LENGTHS:
1000BASE-T (CAT5e or higher is recommended)100m (328 ft)
1000BASE-SX, full-duplex, multi-mode (62.5μm cable)220m
1000BASE-SX, full-duplex, multi-mode (50μm cable)550m
1000BASE-LX, full-duplex, multi-mode (50, 62.5μm cable)550m
1000BASE-LX, full-duplex, single-mode (9μm cable)5km
1000BASE-ZX, full duplex, single-mode (9μm cable)>70km
FIBER MULTI-MODE CONNECTOR TYPES SUPPORTED:
Fiber Port, MTRJ-type (plug-in): SFF Fiber multi-mode 100BASE-FX
Fiber Port, LC-type (plug-in): SFF Fiber multi-mode 100BASE-FX
Fiber Port, SC-type (plug-in), multi-mode 100BASE-FX
Fiber Port, ST-type (twist-lock), multi-mode 100BASE-FX
Fiber Port, 1000BASE-SX, SFP modules
FIBER SINGLE-MODE CONNECTOR TYPES:
Fiber Port, LC-type, Fiber SFF single-mode, 100BASE-FX
Fiber Port, SC-type, single-mode, 100BASE-FX
Fiber Port, 1000BASE-LX, SFP modules
LEDS: PER PORT (ONE SET AT THE PORT)
(see section 5.1.1 for detailed LED configurations)
OPERATING ENVIRONMENT
Ambient Temperature:
................................................... -40° to 140° F (-40° to 60°C) for UL60950 and Component Parts
................................................... -40° to 195° F (-40° to 85°C) for IEC 60068 Type Test short term
Storage Temperature: ............ -60°to 210°F (-50°to 100°C)
Ambient Relative Humidity: . 5% to 95% (non-condensing)
Altitude: ......................................... -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating (humidity protection) optional: Request quote
ALARM RELAY CONTACTS
One NC indicating internal power, one NC software controllable
rating