Purpose:
To set the starting pixel for the Area of Interest or to read the current starting pixel setting.
See Section 3.8 for details.
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4-16
DRAFT
Cmd-ID
R/W-Flag
0xA9
1
Cmd-ID
R/W-Flag
0xA9
0
Cmd-ID
R/W-Flag
0xA9
0
None
Byte 1
Low byte of the starting pixel setting
Byte 2
High byte of the starting pixel setting
1K sensors: 0 (0x0000) to 1023 (0x03FF)
2K sensors: 0 (0x0000) to 2047 (0x07FF)
(When using binary commands, the starting pixel = n +1 where n is the
setting made using this binary command. For example, if you wish to define
pixel 100 as starting pixel, set 99 with the help of this command.)