Configuring the Camera

4.2.4.4 Timer 2

Purpose:
To set Timer 2 or read the current Timer 2 setting. Timer 2 is used when the camera is
operating in free-run mode. See Section 3.2 for details.
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4-14
DRAFT
Cmd-ID
R/W-Flag
0xA7
1
Cmd-ID
R/W-Flag
0xA7
0
Cmd-ID
R/W-Flag
0xA7
0
None
Byte 1
Low byte of the Timer 2 setting
Byte 2
Mid byte of the Timer 2 setting
Byte 3
High byte of the Timer 2 setting
This setting can range from 0x000002 to 0xFFFFFF.
The setting represents a multiplier and the actual value of Timer 2 is
determined by the following:
Timer 2 = setting x 0.0625 µs
To determine the value for this setting, simply divide your desired
Timer 2 value by 0.0625 µs. For example, if you wish to set Timer 2
to 4 µs, the calculation would be as shown below:
setting = 4 µs / 0.0625 µs
setting = 64
In this case, the setting would be 64 (decimal) which translates to a
hexidecimal setting of 0x000040
When you are setting Timer 2, be sure to follow the recommendations
in Section 3.2.2.2.
Data Length
Data
3
Data Length
Data
3
3 Bytes
Data Length
Data
3
3 Bytes
BASLER L100
-
k Series