Check to make sure that the RS-644 serial connection is working OK. You can do
this by starting the Camera Configuration Tool Plus (CCT+). When you start the tool,
a startup graphic should appear and then a window that shows a list of parameter
(If this is the first time that you are using the tool, you will see an empty window with
a drop down menu at the top which says "No port selected". In this case, use the
drop down menu to select the RS-644 port that you want to use. RS-644 ports are
identified in the list by a port number and a *.dll library name. Once you select the
correct port, the list of parameter settings should appear.)
Did the list of parameter settings appear?
Yes
Are you controlling the camera
with an ExSync signal or is the
camera in free-run?
ExSync signal.
Check the setup on your frame
grabber and make sure that the
ExSync signal is not too short. The
period of the ExSync signal must
not be lower than lower than the
minimum shown in Table 3-1.
(On many frame grabbers, the
period of the ExSync signal is
adjusted by changing a setting for
the "line rate". Your line rate should
not exceed the limit given in
Section 1.2.)
Is the ExSync period OK?
Yes
Check your exposure setting.
The exposure time must be
less than the ExSync period.
Is the exposure OK?
Yes
Switch on test image one.
Can the test image be seen?
Yes
Replace the camera.
BASLER L100
k Series
DRAFT
settings should appear.
Free-run.
Correct
No
the
settings.
Correct
No
the
setting.
Go to the
interfacing
No
troubleshooting
chart.
No
Did you set up free-run using the
CCT+ or with binary commands?
Config.
Binary
Tool
Commands
Check to make sure that:
Timer 1 is set no lower than
0.125 µs.
The sum of the Timer 1 setting
plus the Timer 2 setting is no
lower than the minimum
shown in Table 3-3.
Are the settings OK?
Yes
Switch on the test image one.
Can the test image be seen?
Yes
Replace the camera.
Troubleshooting
Go to the
RS-644
serial
communications
troubleshooting
chart.
Correct
the
No
settings.
Go to the
interfacing
No
troubleshooting
chart.