Mechanical Considerations
5.4 Positioning Accuracy of the Sensor Chip
Positioning accuracy of the sensor chip in the horizontal direction (that is, along the line of pixels)
is ± 0.4 mm and in the vertical direction is ± 0.4 mm. Rotational positioning accuracy is as shown
in Figure 5-4. Reference position is the center of the camera housing.
Since the translatory and rotational positioning tolerance depend on each other, the worst case of
maximum rotational and horizontal/vertical mis-positioning cannot occur at the same time.
0.24
Figure 5-4: Rotational Positioning Accuracy
5-4
DRAFT
± 0.4
Position of the center of the sensor's photosensitive area
relative to the sensor's housing
Reference plane
Drawings not to scale
BASLER L100
k Series