3.3 Video Data Output Modes

series cameras can output video data using four different modes: Single 10 Bit mode, Single
L100
k
8 Bit mode, Dual 10 Bit mode and Dual 8 Bit mode. These modes of operation are described in
detail in Section 2.5.5.
You can select the video data output mode using either the Camera Configuration Tool Plus (see
Section 4.1) or binary commands (see Section 4.2).
With the Camera Configuration Tool Plus, you use the Video Data Output Mode setting in the
Output parameter group.
With binary commands, you use the Video Data Output Mode command (see Section 4.2.4.1).

3.4 Integrate Enabled Signal

An output signal called Integrate Enabled (IntEn) is available on L100
enabled signal indicates that an exposure is taking place. The signal will go high when each
exposure begins and go low when the exposure ends. The characteristics of the signal are
described in more detail in Section 2.5.6.
In cases where flash exposure is required, the integrate enabled signal is useful as a flash trigger.