Environmental Requirements; Temperature And Humidity; Ventilation - Basler L100k User Manual

Table of Contents

Advertisement

14
12
10
8
6
4
2
0
300
350
Figure 1-1: Responsivity for L100

1.3 Environmental Requirements

1.3.1 Temperature and Humidity

Housing temperature during operation:
Humidity during operation:
Housing temperature during storage:
Humidity during storage:

1.3.2 Ventilation

Allow sufficient air circulation around the camera to prevent internal heat build-up in your system
and to keep the camera housing temperature during operation below 50 °C. Provide additional
cooling such as fans or heat sinks if necessary.
BASLER L100
k Series
DRAFT
400
450
500
550
Wavelength (nm)
Series Cameras
k
Warning!
Without sufficient cooling, the camera can get hot enough during opera-
tion to cause burning when touched.
600
650
700
750
800
0 °C ... + 50 °C (+ 32 °F ... + 122 °F)
20 % ... 80 %, relative, non-condensing
- 20 °C ... + 80 °C (- 4 °F ... + 176 °F)
5 % ... 95 %, relative, non-condensing
Introduction
850
900
950
1000
1-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents