Operation and Features
• In ExSync, programmable mode, the rising edge of ExSync triggers exposure and charge
accumulation for a pre-programmed period of time. The line is read out and transferred at the
end of the pre-programmed period. The falling edge of ExSync is irrelevant (see Figure 3-4).
A parameter called "Timer 1" is used to set the length of the pre-programmed exposure period.
ExSync
Figure 3-4: ExSync, Programmable Mode
You can set the camera to operate in one of the ExSync controlled exposure modes using either
the Camera Configuration Tool Plus (see Section 4.1) or binary commands (see Section 4.2).
With the Camera Configuration Tool Plus, you use the Exposure Time Control Mode setting in the
Exposure parameter group to set the camera for ExSync operation and to select the edge-
controlled, level controlled or programmable exposure time control mode. If you select the
programmable mode, you must also enter an exposure time. When you enter an exposure time,
the configuration tool will automatically set the "Timer 1" parameter to the correct value.
With binary commands, you must use the Exposure Time Control Mode command to select
ExSync edge-controlled, ExSync level-controlled or ExSync programmable mode (see Section
4.2.4.2). If you choose the programmable mode, you must also use the Timer 1 command to set
the exposure time.
3-4
DRAFT
ExSync Period
Exposure
(Timer 1)
Line Read Out