4.2.7.9 Read Camera Temperature

Purpose:
To read the camera's internal temperature. See Section 3.11 for the allowed maximum
temperature.
Type:
This is a read only command.
Read Command:
Response:
Data Format:
4-28
DRAFT
Cmd-ID
R/W-Flag
0x70
1
Cmd-ID
R/W-Flag
0x70
0
The temperature is given in °C as 8 bit signed number.
If the MSB is 1, a temperature below 0° C is present.
If the MSB is 0, the temperature is 0° C or higher.
For temperatures below 0° C, a two's complement representation is used,
that is, to obtain the actual temperature, the digital output must be inverted and
1 must be added. For example:
A digital output of 11110110 would indicate a negative
value because the MSB is 1
11110110 would be inverted to 00001001
00001001 translates to 9
9 + 1 = 10
The indicated temperature is therefore - 10° C
See more examples in the table below.
Temp.
Digital Output
- 20° C
11101100
- 10° C
1111 0110
0° C
0000 0000
+ 10° C
0000 1010
+ 25° C
0001 1001
+ 50° C
0011 0010
+ 100° C
0110 0100