4.2.4.9 Shading Correction Data Transfer

Purpose:
To enable or disable upload of shading correction data into the camera. See Section 3.6 for
more information on shading correction.
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
BASLER L100
k Series
DRAFT
Cmd-ID
R/W-Flag
0x68
1
Cmd-ID
R/W-Flag
0x68
0
Cmd-ID
R/W-Flag
0x68
0
None
Byte 1
An ID that enables or disables the upload of data
(see the table below).
ID
Data Transfer Mode
0x00
Close registers.
0x50
Open registers for upload of data to non-volatile
memory.
0x51
Open registers for upload of data to volatile
memory.
0x80
Copy data from non-volatile memory to volatile
memory.
Before issuing a command with this data ID, you
must:
1. Issue a 0x68 command to open registers for
upload of data to non-volatile memory.
2. Issue 0x69 commands to upload your shading
correction data.
3. Issue a 0x68 command to close registers.