Area Of Interest Starting Column; Area Of Interest Width In Columns - Basler WOOD BURNING FIREPLACE Wood Burning Fireplace

Table of Contents

Advertisement

4.2.4.11 Area of Interest Starting Column

Purpose:
To set the left starting column for the area of interest or to read the current starting column
setting. See section
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:The starting column can range from 0x0000 to 0x04F6. It can only be set in multiples of
10.
When you set column n using this command, the actual starting column will be n + 1. For example, if
you set the starting column to 0 with this command, the actual starting column = 0 + 1 = 1.

4.2.4.12 Area of Interest Width in Columns

Purpose:
To set the width in columns for the area of interest or to read the current width setting. See
section
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
Basler A500
k
PRELIMINARY
3.11
for details.
Cmd-ID
R/W-Flag
0xA9
Cmd-ID
R/W-Flag
0xA9
Cmd-ID
R/W-Flag
0xA9
None
Byte 1
Low byte of the starting pixel setting
Byte 2
High byte of the starting pixel setting
3.11
for details.
Cmd-ID
R/W-Flag
0xAB
Cmd-ID
R/W-Flag
0xAB
Cmd-ID
R/W-Flag
0xAB
None
Byte 1
Low byte of the length in pixel setting
Byte 2
High byte of the length in pixel setting
The width in columns can range from 0x000A to 0x0500. The width can only
be set in multiples of 10 (A504k/kc, A501k/kc) or 40 (A503k).
Data Length
1
2
Data Length
0
2
Data Length
0
2
Data Length
1
2
Data Length
0
2
Data Length
0
2
Configuring the Camera
Data
-
Data
2 Bytes
Data
2 Bytes
Data
-
Data
2 Bytes
Data
2 Bytes