1.11 Environmental Requirements
1.11.1 Temperature and Humidity
Housing temperature during operation:
Housing temperature during operation
for acA2000-165 and acA2040-90 only:
Housing temperature according to UL 60950-1:
Ambient temperature according to UL 60950-1:
UL 60950-1 test conditions: no lens attached to the camera and without efficient heat
dissipation; ambient temperature kept at 30 °C (+86 °F).
Humidity during operation:
Storage temperature:
Storage humidity:
Temperature Measuring Spot
You must determine the camera housing temperature on a specific measuring spot. Its location on
the camera housing is indicated in the figure below.
Housing temperature
measuring spot
Fig. 32: Location of the Housing Temperature Measuring Spot on the Camera Housing
Basler ace USB 3.0
Specifications, Requirements, and Precautions
0 °C ... +50 °C (+32 °F ... +122 °F)
0 °C ... +60 °C (+32 °F ... +140 °F)
max. 70 °C (+158 °F)
max. 30 °C (+86 °F)
20 % ... 80 %, relative, non-condensing
-20 °C ... +80 °C (-4 °F ... +176 °F)
20 % ... 80 %, relative, non-condensing