Requirements
Device temperature during operation
Device temperature during storage
Humidity
Ambient temperature according to
UL 60950-1
UL 60950-1 test conditions: no lens attached to the camera and without efficient heat dissipation; ambient
temperature kept at +50 °C (+122 °F).
* Temperature measured at the hottest point on the board. This point is significantly hotter than the other parts on
the board. See
Figure
14.
† Temperature measured at the outside of the camera. See
Table 6: Temperature and Humidity Requirements
Temperature Measurement Points
Fig. 14: Device Temperature Measurement Point (Bare Board Models)
Fig. 15: Device Temperature Measurement Point (S-mount and CS-mount Models)
Basler dart BCON
dart Bare Board Models
0 °C ... +75 °C *
(+32 °F ... +167 °F) *
-20 °C ... +80 °C
(-4 °F ... +176 °F)
20% ... 80%, relative, non-condensing
max. +50 °C (+122 °F)
Figure
Temperature measurement point for
dart BCON bare board models
Temperature measurement point for
dart BCON S-mount and CS-mount models
Technical Specifications and Requirements
dart S-mount and
CS-mount Models
0 °C ... +50 °C †
(+32 °F ... +122 °F) †
15.