ABB REO 517 Applications Manual page 44

Multi-function terminals for railway application
Table of Contents

Advertisement

34
Logic function blocks
7DEOH 
7UXWK WDEOH IRU WKH ,19 IXQFWLRQ EORFN
,1387
287
1
0
0
1
&RQWUROODEOH JDWH *7
The GT function block is used for controlling if a signal should be able to pass or not
depending on a setting. The function block (figure 7) has one input, designated GTnn-
INPUT, where nn presents the serial number of the block. Each GT circuit has one out-
put, GTnn-OUT. Each gate further has a Operation On/Off which controls if the INPUT
is passed to the OUT or not.
GTnn
INPUT
Operation = On
)LJXUH 
)XQFWLRQ EORFN GLDJUDP RI WKH FRQWUROODEOH JDWH *7 IXQFWLRQ
The output signal from the GT function block is set to 1 if the input signal is 1 and Op-
eration = On elsewhere it is set to 0. See truth table below.
7DEOH 
7UXWK WDEOH IRU WKH *7 IXQFWLRQ EORFN
,1387
0
1
0
1
OUT
&
xx00000530.vsd
2SHUDWLRQ
Off
Off
On
On
&RPPRQ IXQFWLRQV
287
0
0
0
1