ABB REO 517 Applications Manual page 201

Multi-function terminals for railway application
Table of Contents

Advertisement


Apparatus control
2. Reservation signal from the bay, which is to be operated
3. Transfer of acknowledgement and actual position indications from the other bays
4. Performed selection is presented on the station HMI
5. Execution of the command from the station HMI
6. Release (cancel) of the reservation
1.Select
5.Execute
2.Reserve
3.Indication
Select
6.Release
REO 517
Apparatus
Control
Bay 1
)LJXUH  7KH UHVHUYDWLRQ PHWKRG
$XWRPDWLF IXQFWLRQV
The apparatus control has inputs to be connected to automatic functions, for example,
delayed autoreclosing. When an automatic operation program must take control of an
apparatus, it must check if this is permitted. Automatic operations are permitted when
these conditions are fulfilled:
Operator place is not local
The apparatus is not selected
The apparatus is not reserved
The concerned apparatus is not blocked for operation
Position indications are not blocked
The function, which operates automatically, also first determines if automatic operation
is permitted.
Selected
4
Reserve
Execute
Release
1
2
5
6
3
Indication
REO 517
Apparatus
Control
Bay 2
&KDSWHU 
2.Reserve
3.Indication
6.Release
REO 517
Apparatus
Control
Bay 3
en02000570.vsd
&RQWURO
191

Advertisement

Table of Contents
loading

Table of Contents