Erps Commands - Supermicro SSE-G2252 User Manual

Hide thumbs Also See for SSE-G2252:
Table of Contents

Advertisement

Chapter 35: ERPS Commands
35
ERPS C
OMMANDS
The G.8032 recommendation, also referred to as Ethernet Ring Protection
Switching (ERPS), can be used to increase the availability and robustness
of Ethernet rings.
This chapter describes commands used to configure ERPS.
Table 35-1: ERPS Commands
Command
Function
erps
Enables ERPS globally on the switch
erps domain
Creates an ERPS ring and enters ERPS configuration mode
control-vlan
Adds a Control VLAN to an ERPS ring
enable
Activates the current ERPS ring
guard-timer
Sets the timer to prevent ring nodes from receiving outdated
R-APS messages
holdoff-timer
Sets the timer to filter out intermittent link faults
major-domain
Specifies the ERPS ring used for sending control packets
meg-level
Sets the Maintenance Entity Group level for a ring
mep-monitor
Specifies the CCM MEPs used to monitor the link on a ring node ERPS
node-id
Sets the MAC address for a ring node
non-erps-
Sends non-standard health-check packets when in protection
dev-protect
state
non-revertive
Enables non-revertive mode, which requires the protection state
on the RPL to manually cleared
propagate-tc
Enables propagation of topology change messages from a
secondary ring to the primary ring
raps-def-mac
Sets the switch's MAC address to be used as the node identifier
in R-APS messages
raps-without-
Terminates the R-APS channel at the primary ring to sub-ring
vc
interconnection nodes
ring-port
Configures a node's connection to the ring through the east or
west interface
rpl neighbor
Configures a ring node to be the RPL neighbor
rpl owner
Configures a ring node to be the RPL owner
version
Specifies compatibility with ERPS version 1 or 2
wtr-timer
Sets timer to verify that the ring has stabilized before blocking
the RPL after recovery from a signal failure
clear erps
Clears statistics, including SF, NR, NR-RB, FS, MS, Event, and
statistics
Health protocol messages
erps clear
Manually clears protection state which has been invoked by a
Forced Switch or Manual Switch command, and the node is
operating under non-revertive mode; or before the WTR or WTB
timer expires when the node is operating in revertive mode