Download  Print this page

Error Clear - Mitsubishi Electric FX5 User Manual

Melsec iq-f series.
Hide thumbs
   
1
2
3
4
5
6
7
Table of Contents
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488

Advertisement

Error Clear

This function clears all the existing continuation errors at once.
Errors that can be cleared
Error code
1080H
1090H
1800H
1810H, 1811H
1900H
1920H
1921H
1FE0 to 1FE6H, 2008H
2120H, 2121H
2400H
2440H, 2441H
2522H
2801H
2820H, 2821H, 2822H, 2823H
2840H
3360H to 3362H
3380H
3400H to 3406H, 3420H, 3500H, 3502H to 3506H, 350AH, 350C to 350FH,
3510H to 351EH, 3580H, 3581H, 3600H, 3611H to 361CH, 3621H to 362CH,
3631H to 363CH, 3641H to 364CH, 3651H to 365CH, 3661H to 366CH,
3671H to 367CH, 3681H to 368CH, 3691H to 369CH, 36A1H to 36ACH,
36B1H to 36BCH, 36F0H
3780H
3781H
How to clear errors
Errors can be cleared in two ways:
■Using the engineering tool
Clear errors with the module diagnostics function of engineering tool. (GX Works3 Operating Manual)
■Using SM/SD
Clear errors by operating SM/SD.
1.
Check SD0 (Latest self-diagnostics error code) to identify what errors are detected.
2.
Clear the cause of each of the currently detected continuation errors.
3.
Turn off and on SM50 (error reset).
Precautions
This section describes some precautions to take when using the error clear function:
• Since the function clears all of the currently detected continuation errors at once, errors that should not yet be cleared may
be cleared.
• Use the RST instruction to reset each annunciator individually.
Error name
ROM write count error
Battery error
Annunciator ON
Operation error
Constant scan time error
IP address setting error
IP address writing/clear request simultaneous detection
Module configuration error
Memory card error
Module verification error
Module major error
Invalid interrupt
Module specification error
Device specification error
File name specification error
Nesting depth error
Pointer execution error
Operation error
High-speed comparison table maximum excess error
Preset value range outside error
21.1 Self-Diagnostics Function
21 RAS FUNCTIONS
159