Download  Print this page

Precautions To Take When Using The Data Logging Function - Mitsubishi Electric FX5 User Manual

Melsec iq-f series.
Hide thumbs
   
1
2
3
4
5
6
7
Table of Contents
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488

Advertisement

19.14
Precautions to Take When Using the Data Logging
Function
This section describes precautions to take when using the data logging function.
Mutual exclusion of the data logging function
This section describes the mutual exclusion of the data logging function.
■When another function is executed during the execution of the data logging function
The following table lists the cases when another function is executed during the execution of the data logging function.
Function that has been
Function to be
already executed
executed later
Data logging function
Data logging function
Memory dump function
Data backup function
Data restoration function
■When the data logging function is executed during the execution of another function
The following table lists the cases when the data logging function is executed during the execution of another function.
Function that has been
Function to be
already executed
executed later
Memory dump function
Data logging function
Data backup function
Data restoration function
Locations from which data logging can be performed
Data logging cannot be performed from multiple locations to the same setting number. The CPU module supports data
logging performed concurrently at a maximum of 4 locations assigned to setting numbers 1 to 4.
Retention and clearance of data logging settings
The data logging settings registered in the CPU module are latched and thus survive across a power cycle (power off and on)
or reset of the CPU module in normal cases. In the following cases, however, the data logging status is cleared to the
unregistered state and therefore the setting data must be written again:
• The CPU module is turned off and on or reset without an SD memory card that contains the data logging setting file.
• The replaced SD memory card does not contain the data logging setting file and the CPU module is turned off and on or
*1
reset.
*1 If the data logging setting file contained in the replacement (new) SD memory card is different from that contained in the replaced (old)
SD memory card, the data logging setting file contained in the replacement SD memory card becomes registered.
Operation that occurs when trigger logging is resumed
If data logging is stopped or collection is suspended before the completion of trigger logging and subsequently data logging is
run again, data collection begins from the initial state before trigger logging, rather than continuing from the last time.
Operation
When the data logging is started using the CPU Module Logging Configuration Tool to the
same data logging setting number, the data logging to be executed later cannot be executed.
However, the data logging to be executed later can be executed to a data logging setting
number different from the data logging setting number currently being executed.
For the execution of multiple data loggings, the data logging settings stored in different target
memory areas cannot be executed at the same time.
The data logging function and memory dump function cannot be used simultaneously.
The data backup function cannot be executed while a logging setting file is being written/
deleted or a logging setting is being registered/cleared.
The data restoration function cannot be executed while a logging setting file is being written/
read/deleted or a logging setting is being registered/cleared.
Operation
The data logging function and memory dump function cannot be used simultaneously.
While the data backup function is being executed, a logging setting file cannot be written/
deleted and a logging setting cannot be registered/cleared.
While the data restoration function is being executed, a logging setting file cannot be written/
read/deleted and a logging setting cannot be registered/cleared.

19.14 Precautions to Take When Using the Data Logging Function

19 DATA LOGGING FUNCTION