High-speed comparison table

The high-speed comparison table is explained below.
Used to set high-speed comparison table for high-speed counters.
Parameter setting
Sets match output setting for high-speed counters.
■CPU module
Navigation window  [Parameter]  [FX5UCPU]  [Module Parameter]  [High Speed I/O]  "Input Function"  "High
Speed Counter"  "Detail Setting"  "High Speed Compare Table"
Window
Displayed items
Item
Counter CH
Comparison Type
Output Destination Device
Comparison Value 1
Specification Method
Comparison Value 1 Direct
Comparison Value 1 Indirect
Comparison Value 2
Specification Method
Comparison Value 2 Direct
Comparison Value 2 Indirect
24 HIGH-SPEED INPUT/OUTPUT FUNCTION
204
24.1 High-speed Counter Function
Description
Set the counter CH of coincidence output target.
Set comparison type.
Sets output destination device for output comparison
results of comparison value 1 and comparison value 2.
Sets the specification method of comparison value 1.
Sets value (comparison value 1) to be compared with
current value of high-speed counter. (When direct
specification is selected)
Sets device (comparison value 1) to be compared with
current value of high-speed counter. (When indirect
specification is selected)
If band comparison is set to comparison type, sets the
specification method of comparison value 2.
If band comparison is set to comparison type, sets value
(comparison value 2) to be compared with current value
of high-speed counter. (When direct specification is
selected)
If band comparison is set to comparison type, sets
device (comparison value 2) to be compared with
current value of high-speed counter. (When indirect
specification is selected)
Setting range
Disable, CH1 to CH8
• Set
• Reset
• Self Reset
• Band Area Comparison
Bit device (Y, M), Interrupt pointer (I16 to I23)
• Direct Specification
• Indirect Specification
-2147483648≤Comparison value 1≤+2147483647
Word device (D, R)
• Direct Specification
• Indirect Specification
Comparison value 1≤Comparison value
2≤+2147483647
Word device (D, R)
Default
Disable
Set
Direct
Specificati
on