Download  Print this page

Timer (t/st) - Mitsubishi Electric FX5 User Manual

Melsec iq-f series.
Hide thumbs
   
1
2
3
4
5
6
7
Table of Contents
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488

Advertisement

Timer (T/ST)

Device whereby measurement starts when the timer coil is turned ON, time up occurs when current value reaches the setting
value, and the contact is turned ON. The timer is an addition type counter. When time is up, the current value and setting
value are the same value.
Types of timers
There are timers (T) for which current value is maintained in 16 bits, and retentive timers (ST) that maintain the current value
even when the coil is turned OFF.
*1 Current value of timers (T) becomes "0" when the coil is turned OFF.
■Timer (T)
Measurement starts when the timer's coil is turned ON. Time up occurs when the current value of the timer matches the
setting value and the timer's contact is turned ON. When the timer's coil is turned OFF, the current value becomes "0" and the
timer's contact is turned OFF.
2)
X0
K10
T0
1)
T0
Y10
3)
■Retentive timer (ST)
Measures time for which the coil is ON. Measurement starts when the retentive timer's coil is turned ON, and when the current
value matches the setting value (time up), the retentive timer's contact is turned ON. The current value and ON/OFF status of
the contact are maintained even if the retentive timer's coil is turned OFF. When the coil is turned back ON, measurement
resumes from the current value maintained. The current value is cleared and the retentive timer is turned OFF by the RST
ST instruction.
2)
X0
K200
ST0
1)
ST0
Y10
3)
X1
4)
RST ST0
■Low-speed timer/Timer/High-speed timer (T/ST)
Low-speed timers, timers and high-speed timers are the same device. The timer is specified (by instruction) as a low-speed
timer, timer, or high-speed timer. If for example, you specify "OUT T0," the timer is a low-speed timer (100 ms); if you specify
"OUTH T0," it is a timer (10 ms); if you specify "OUTHS T0," it is a high-speed timer (1 ms). The same goes for retentive
timers.
■Routine timer (T)
The routine timer is a timer (100ms) that can operate even with a program that is not necessarily executed with every scan.
Eight timers can be used at the maximum. This timer counts when the OUT T instruction, the ANS instruction, or the END
instruction is executed.
To use a routine timer, it is necessary to set the parameter. (Page 309 Routine timer setting)
*1
ON
X0
OFF
ON
T0 coil (1))
OFF
T0 contact (3))
OFF
ON
X0
OFF
ON
ST0 coil (1))
OFF
Current value of
0
ST0
Current value is held even if
the coil (1)) is turned OFF.
ST0 contact (3))
OFF
RST ST0
instruction (4))
1
ON
second
15 seconds
1
150
150
Contact remains ON even if
the coil (1)) is turned OFF.
5
seconds
151
199
200
0
Instruction
execution
26 DEVICES
307
26.2 User Devices
26