Operating procedure
1.
SM9350 (CPU module auto exchange function enable/disable flag) is turned OFF (enable).
2.
Set SD9350 (Operation mode setting) to 1 or 2
3.
With SD9351 (CPU module auto exchange function restoration target data setting), set the data to be restored when
executing restoration with CPU module auto exchange.
4.
Make each setting with SD9352 (CPU module auto exchange function setting) b1
5.
Turn on SM1351 (Data backup execution request).
SM1351
OFF
SM1350
OFF
SM9350
OFF
END END END END END
*1 Only 1 (CPU module auto exchange mode (delete existing data)) is valid with firmware version earlier than "1.050".
*2 This operation is required when the firmware version is "1.050" and later.
If the backup processing is completed with an error and SM953 (Data backup error check flag) turns on, check SD953
(Backup error cause), take actions, and then back up the data again as required.
The execution status of the backup processing can be checked with SD1350 (Number of uncompleted
folders/files of CPU module data backup/restoration) and SD1351 (Progression status of CPU module data
backup/restoration). (Page 168 Progress of the backup/restoration processing)

Checking backup errors

When an error has occurred, a diagnostic error is not detected and an error code is stored in SD953 (Backup error cause).
(Page 401 List of error codes)

Precautions

The following describes the precautions for the backup function.
Prohibited operation during execution of the backup processing
Do not perform the following operations during execution of the backup processing.
• Attaching or detaching the SD memory card
• Powering off or resetting the CPU module
The above mentioned operations leave the backup data in the SD memory card in an incomplete state which is in the middle
of the backup processing. Do not use these data for a restoration. If these data are used, the restoration completes with an
error.
22 DATA BACKUP/RESTORATION FUNCTION
172
22.1 Backup Function
*1
.
(1)
(3)
ON
(2)
ON
ON
END END END
*2
*2
(1) Turn on SM1351.
(4)
(2) The system turns on SM1350 (Data backup
status flag).
(3) System file for CPU module auto exchange
function is created, and the system turns SM9350
(CPU module auto exchange function enable/
disable flag) ON (disable).
(4) The system turns off SM1351 after the backup
(5)
processing is completed.
(5) The system turns off SM1350.
END END END