Special relays/
Function
special
registers
SM5052
CH1 pulse width measurement
complete
SM5053
CH2 pulse width measurement
complete
SM5054
CH3 pulse width measurement
complete
SM5055
CH4 pulse width measurement
complete
SM5056
CH5 pulse width measurement
complete
SM5057
CH6 pulse width measurement
complete
SM5058
CH7 pulse width measurement
complete
SM5059
CH8 pulse width measurement
complete
SM5060
CH9 pulse width measurement
complete
SM5061
CH10 pulse width measurement
complete
SM5062
CH11 pulse width measurement
complete
SM5063
CH12 pulse width measurement
complete
SM5068
CH1 measurement mode
SM5069
CH2 measurement mode
SM5070
CH3 measurement mode
SM5071
CH4 measurement mode
SM5072
CH5 measurement mode
SM5073
CH6 measurement mode
SM5074
CH7 measurement mode
SM5075
CH8 measurement mode
SM5076
CH9 measurement mode
SM5077
CH10 measurement mode
SM5078
CH11 measurement mode
SM5079
CH12 measurement mode
SD5021, SD5020
CH1 rising edge ring counter value
SD5023, SD5022
CH1 falling edge ring counter value
SD5025, SD5024
CH1 pulse width latest value
SD5027, SD5026
CH1 pulse width maximum value
SD5029, SD5028
CH1 pulse width minimum value
SD5031, SD5030
CH1 period latest value
SD5033, SD5032
CH1 period maximum value
SD5035, SD5034
CH1 period minimum value
SD5041, SD5040
CH2 rising edge ring counter value
SD5043, SD5042
CH2 falling edge ring counter value
SD5045, SD5044
CH2 pulse width latest value
SD5047, SD5046
CH2 pulse width maximum value
SD5049, SD5048
CH2 pulse width minimum value
SD5051, SD5050
CH2 period latest value
SD5053, SD5052
CH2 period maximum value
SD5055, SD5054
CH2 period minimum value
SD5061, SD5060
CH3 rising edge ring counter value
SD5063, SD5062
CH3 falling edge ring counter value
24 HIGH-SPEED INPUT/OUTPUT FUNCTION
266
24.3 Pulse Width Measurement Function
Description
These flags turn ON at the end of the 1st pulse width
measurement on the target channel. (They remain ON during
measurement in the always measurement mode.)
The measurement mode of the target channel can be checked by
these flags. (To change the measurement mode during operation,
use this special relay.)
OFF: Always measurement mode
ON: 1 time measurement mode
The ring counter value when the rising edge is detected is stored.
The ring counter value when the falling edge is detected is stored.
The latest value of the pulse width is stored.
The maximum value of the pulse width is stored.
The minimum value of the pulse width is stored.
The latest value of the period is stored.
The maximum value of the period is stored.
The minimum value of the period is stored.
The ring counter value when the rising edge is detected is stored.
The ring counter value when the falling edge is detected is stored.
The latest value of the pulse width is stored.
The maximum value of the pulse width is stored.
The minimum value of the pulse width is stored.
The latest value of the period is stored.
The maximum value of the period is stored.
The minimum value of the period is stored.
The ring counter value when the rising edge is detected is stored.
The ring counter value when the falling edge is detected is stored.
Default
R/W
OFF
R
*1
ON
R/W
00000000H
R
00000000H
R
00000000H
R
00000000H
R/W
FFFFFFFFH
R/W
00000000H
R
00000000H
R/W
FFFFFFFFH
R/W
00000000H
R
00000000H
R
00000000H
R
00000000H
R/W
FFFFFFFFH
R/W
00000000H
R
00000000H
R/W
FFFFFFFFH
R/W
00000000H
R
00000000H
R