Hold/Clear of output at CPU STOP and at CPU stop error

1
This function sets Hold/Clear of the auto refresh device output when CPU module operation of the cyclic master is at STOP or
at CPU stop error.
The following shows the servo amplifier status at CPU STOP and at stop error.
Motion mode
■Motion control axis
The servo amplifier stops the servo motor in the manner commanded by the controller.
■Motion non-control axis
The servo amplifier decelerates the servo motor to a stop.

Remote reset

Resetting can be done by sending the reset command to the specified station. The reset command can be sent from the
Remote Operation window of GX Works3.
Refer to the following for details.
Page 12 Remote Operation

Clock function

This function is used to acquire time information from the grand master (the station serving as a clock source) via CC-Link IE
TSN so that this information may be used for the time management of functions performed by the servo amplifier, such as
alarm history. The time synchronization protocol for the grand master and the servo amplifier uses IEEE1588 or
IEEE802.1AS.
1 CC-Link IE TSN