No.
Name
SM8016
Time read display is stopped
±30 seconds correction
SM8017
SM8019
Real time clock error
SM8020
Zero
SM8021
Borrow
SM8022
Carry
SM8023
Real time clock access error
SM8026
RAMP mode
SM8029
Instruction execution complete
SM8031
Non-latch memory all clear
SM8032
Latch memory all clear
SM8033
Memory hold stop
SM8034
All output disable
SM8039
Constant scan mode
SM8040
STL transfer disable
SM8041
Transfer start
SM8042
Start pulse
SM8043
Zero return complete
SM8044
Zero point condition
SM8045
All output reset disable
SM8046
STL state ON
SM8047
Enable STL monitoring
SM8048
Annunciator ON
SM8049
Enable annunciator monitoring
SM8050
I00 disable
SM8051
I10 disable
SM8052
I20 disable
SM8053
I30 disable
SM8054
I40 disable
SM8055
I50 disable
SM8056
I60 disable
SM8057
I70 disable
SM8058
I80 disable
Description
When SM8016 turns ON, the time display is stopped.
At the edge from OFF to ON, the RTC is set to the nearest minute.
(When the second data is from 0 to 29, it is set to 0. When the
second data is from 30 to 59, it is set to 0 and the minute data is
incriminated by "1".)
When the data stored in special registers is outside the allowable
time setting range, this device turns ON.
OFF: Zero flag OFF
ON: Zero flag ON
OFF: Borrow flag OFF
ON: Borrow flag ON
OFF: Carry flag OFF
ON: Carry flag ON
SM8023 turns ON at the time of RTC access (reading/writing)
error occurrence.
OFF: Standard mode
ON: RAMP mode
OFF: Instruction execution not complete
ON: Instruction execution complete
OFF: No clear
ON: Non-latch memory all clear
OFF: No clear
ON: Latch memory all clear
OFF: Clear
ON: Hold
OFF: Normal operation
ON: All output disable
OFF: Normal operation
ON: Constant scan mode
OFF: Normal operation
ON: Transfer disable
Transfer from initial state is enabled in automatic operation mode
Pulse output is given in response to a start input
Set this in the last state of zero return mode
Set this when machine zero return is detected
Disables the 'all output reset' function when the operation mode is
changed
ON when SM8047 is ON and any state (S) is active
SD8040 to SD8047 are enabled when SM8047 is ON
ON when SM8049 is ON and any annunciator (F) is ON.
SD8049 is enabled when SM8049 is ON.
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
OFF: Interrupt enabled
ON: Interrupt disabled
R/W
R/W
R/W
R
R
R
R
R
R/W
R
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R/W
R/W
R/W
R
R/W
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
APPX
Appendix 1 Special Relay List